Literature DB >> 6502252

Accuracy and precision of regional multiharmonic Fourier analysis of gated blood-pool images.

J Machac, S F Horowitz, D Broder, S J Goldsmith.   

Abstract

In order to estimate the precision and accuracy of parameters derived from segmental multiharmonic Fourier analysis of gated blood-pool images, a Monte Carlo computer noise simulation was tested on five sample regional time-activity curves. The first three Fourier harmonics were retained and the precision and accuracy of parameters of ventricular function were calculated, varying the ejection fraction, segment size, and framing rate. Precision improved with higher ejection fraction, higher counts per frame, or higher framing rate. There was no change in precision as the framing rate changed at fixed total counts. Accuracy changed little with changing framing rate. Thus, for segmental analysis there is no advantage to using a higher framing rate. Regions five or more pixels in size are recommended for reliable results. This study provides useful information for the optimization of acquisition and processing conditions for regional gated blood-pool analysis.

Mesh:

Year:  1984        PMID: 6502252

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  6 in total

1.  Cardiac gated equilibrium radionuclide angiography and multiharmonic Fourier phase analysis: optimal acquisition parameters in arrhythmogenic right ventricular cardiomyopathy.

Authors:  D Daou; R Lebtahi; M Faraggi; Y Petegnief; D Le Guludec
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

2.  Ventricular function during the acute rejection of heterotopic transplanted heart: gated blood-pool studies.

Authors:  H Valette; M H Bourguignon; M Desruennes; P Merlet; D Le Guludec; M C Gregoire; D Agostini; M Rigaud; I Gandjbakhch; A Cabrol
Journal:  Eur J Nucl Med       Date:  1991

Review 3.  First-pass radionuclide angiocardiography with single-crystal gamma cameras.

Authors:  K Nichols; E G DePuey; A Rozanski
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

4.  Effect of pacing rate on regional left ventricular wall motion. Assessment by quantitative analysis of equilibrium radionuclide angiography.

Authors:  Z X He; J Darcourt; O Migneco; J P Camous; J Benoliel; F Bussière; M Baudouy; P Morand
Journal:  Int J Card Imaging       Date:  1995-09

5.  Phase mapping of radionuclide gated biventriculograms in patients with sustained ventricular tachycardia or Wolff-Parkinson-White syndrome.

Authors:  D Le Guludec; M Bourguignon; C Sebag; H Valette; A Sirinelli; J M Davy; A Syrota; G Motte
Journal:  Int J Card Imaging       Date:  1987

6.  Characterization and automatic identification of ECG conduction abnormalities using segmental multiharmonic Fourier analysis of gated blood-pool scintigrams.

Authors:  J Machac; S F Horowitz; R Fagerstrom; R Levine; S J Goldsmith
Journal:  Eur J Nucl Med       Date:  1985
  6 in total