Literature DB >> 6482503

Video and scanning microdensitometer-based imaging systems in autoradiographic densitometry.

P Ramm, J H Kulick, M P Stryker, B J Frost.   

Abstract

The characteristics of computer-assisted imaging devices (CIDs) incorporating charge-coupled device cameras, vidicon cameras and scanning microdensitometers (SMDs) are compared. Advantages of vidicons include their low cost, the option of real-time imaging, continuously variable optical magnification and the wide choice of available vidicon elements. Disadvantages include densitometric non-linearities and, with some vidicons, lack of dynamic range. A CID comprising a laboratory minicomputer, image processing device, vidicon and SMD scanners and our 'PANDA' image analysis routines is described. Software corrections for vidicon errors are evaluated by comparing the densitometric accuracy of the CID receiving input from the vidicon camera and from the SMD. The scanners exhibit similar densitometric accuracy and linearity, and acceptable between-session repeatability. It is concluded that densitometric precision of a corrected vidicon scanner is not the limiting factor for quantitative autoradiographic densitometry.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6482503     DOI: 10.1016/0165-0270(84)90028-1

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  7 in total

1.  Ultra-high performance, solid-state, autoradiographic image digitization and analysis system.

Authors:  J L Lear; J P Pratt; R F Ackermann; J Plotnick; S Rumley
Journal:  Metab Brain Dis       Date:  1990-06       Impact factor: 3.584

Review 2.  A user's guide for avoiding errors in absorbance image cytometry: a review with original experimental observations.

Authors:  P Chieco; A Jonker; C Melchiorri; G Vanni; C J Van Noorden
Journal:  Histochem J       Date:  1994-01

3.  A new method for quenching correction leads to revisions of data in receptor autoradiography.

Authors:  K Zilles; K zur Nieden; A Schleicher; J Traber
Journal:  Histochemistry       Date:  1990

4.  Local cerebral glucose utilization in the Ammon's horn and dentate gyrus of the rat brain.

Authors:  A Wree; A Schleicher; K Zilles; T Beck
Journal:  Histochemistry       Date:  1988

Review 5.  The determination of the local cerebral glucose utilization with the 2-deoxyglucose method.

Authors:  A Wree; A Schleicher
Journal:  Histochemistry       Date:  1988

6.  The ontogenetic development of serotonin (5-HT1) receptors in various cortical regions of the rat brain.

Authors:  K Zilles; A Schleicher; T Glaser; J Traber; M Rath
Journal:  Anat Embryol (Berl)       Date:  1985

7.  Image analysis of the histochemical demonstration of glucose-6-phosphatase activity in rat liver.

Authors:  R Hildebrand; A Schleicher
Journal:  Histochemistry       Date:  1986
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.