Literature DB >> 6477979

Vernier acuity with noisy lines: estimation of relative position uncertainty.

Y Y Zeevi, S S Mangoubi.   

Abstract

Vernier acuity experiments were carried out to obtain estimates of the minimal number of spatial samples extracted, and of the equivalent noise figure characterizing inherent limitations of the visual system in relative position detection tasks. Results are interpreted by modelling the visual system as an ideal detector limited by external noise and internal position uncertainty resulting from structural limitations and neural noise. Accordingly, we estimate that less than ten samples per line are extracted by the observer and that the equivalent noise figure or position uncertainty is of the order of 20 arc s.

Mesh:

Year:  1984        PMID: 6477979     DOI: 10.1007/bf00336962

Source DB:  PubMed          Journal:  Biol Cybern        ISSN: 0340-1200            Impact factor:   2.086


  8 in total

1.  The staircrase-method in psychophysics.

Authors:  T N CORNSWEET
Journal:  Am J Psychol       Date:  1962-09

2.  Direction sense of the eye.

Authors:  E LUDVIGH
Journal:  Am J Ophthalmol       Date:  1953-06       Impact factor: 5.258

3.  Reconstructing the visual image in space and time.

Authors:  H B Barlow
Journal:  Nature       Date:  1979-05-17       Impact factor: 49.962

4.  Visual hyperacuity:spatiotemporal interpolation in human vision.

Authors:  M Fahle; T Poggio
Journal:  Proc R Soc Lond B Biol Sci       Date:  1981-11-24

5.  The Ferrier Lecture, 1980. Critical limiting factors in the design of the eye and visual cortex.

Authors:  H B Barlow
Journal:  Proc R Soc Lond B Biol Sci       Date:  1981-05-07

6.  The use of different cues in vernier acuity.

Authors:  R J Watt; M J Morgan; R M Ward
Journal:  Vision Res       Date:  1983       Impact factor: 1.886

7.  Mechanisms responsible for the assessment of visual location: theory and evidence.

Authors:  R J Watt; M J Morgan
Journal:  Vision Res       Date:  1983       Impact factor: 1.886

8.  Spatial configurations for visual hyperacuity.

Authors:  G Westheimer; S P McKee
Journal:  Vision Res       Date:  1977       Impact factor: 1.886

  8 in total
  2 in total

1.  A perceptually completed whole is less than the sum of its parts.

Authors:  Jason M Gold
Journal:  Psychol Sci       Date:  2014-05-05

2.  Reduced sampling efficiency causes degraded Vernier hyperacuity with normal aging: Vernier acuity in position noise.

Authors:  Roger W Li; Brian Brown; Marion H Edwards; Charlie V Ngo; Sandy W Chat; Dennis M Levi
Journal:  Sci Rep       Date:  2012-03-05       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.