Literature DB >> 6476234

Method for intraoperative assessment of organ perfusion and viability using a miniature oxygen sensor.

H B Kram, W C Shoemaker.   

Abstract

A specially designed miniaturized Clark polarographic electrode was used to measure organ surface oxygen tension during surgical operations in 10 patients as a means of determining tissue perfusion and viability. When applied to organ surfaces, the sensor noninvasively provides real-time assessment of tissue PO2. Values obtained are dependent on both arterial PO2 and local blood flow and therefore may be used to quantitatively assess local oxygen delivery (perfusion). Measured values may be compared with arterial PO2 or to areas of certain normal perfusion on the same organ to better define the adequacy of local oxygen transport. Tissue temperature is independently measured and may be used to assess the metabolic activity of the tissue monitored. Organ surface oximetry using the miniature PO2 sensor is a practical and repeatable method for the intraoperative assessment of organ perfusion and viability.

Entities:  

Mesh:

Year:  1984        PMID: 6476234     DOI: 10.1016/0002-9610(84)90482-3

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  6 in total

1.  The changes in brain surface, intracerebral tissue, and transconjunctival oxygen tension during hypo- and hyperventilation.

Authors:  T Arai; D A Silvern; P M Gupte; K Shibutani; D E Lees
Journal:  J Anesth       Date:  1990-04       Impact factor: 2.078

2.  Continuous intraoperative monitoring of hepatic blood perfusion using a noninvasive surface electrode.

Authors:  C Piasecki; A M Seifalian
Journal:  Dig Dis Sci       Date:  1990-03       Impact factor: 3.199

3.  Impaired oxygenation of gastric mucosa in portal hypertension. The basis for increased susceptibility to injury.

Authors:  I J Sarfeh; H Soliman; K Waxman; M Coccia; E B Rypins; H X Bui; A Tarnawski
Journal:  Dig Dis Sci       Date:  1989-02       Impact factor: 3.199

4.  Tissue oximetry: an interim report.

Authors:  T K Hunt; J Rabkin; J A Jensen; K Jonsson; K von Smitten; W H Goodson
Journal:  World J Surg       Date:  1987-04       Impact factor: 3.352

Review 5.  Optimising organ perfusion in the high-risk surgical and critical care patient: a narrative review.

Authors:  Thomas Parker; David Brealey; Alex Dyson; Mervyn Singer
Journal:  Br J Anaesth       Date:  2019-05-02       Impact factor: 9.166

6.  Assessment of tissue oxygen tension: comparison of dynamic fluorescence quenching and polarographic electrode technique.

Authors:  Andrew D Shaw; Zheng Li; Zach Thomas; Craig W Stevens
Journal:  Crit Care       Date:  2002-01-10       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.