Literature DB >> 2137770

Continuous intraoperative monitoring of hepatic blood perfusion using a noninvasive surface electrode.

C Piasecki1, A M Seifalian.   

Abstract

Continuous noninvasive measurement of local blood flow at one or more chosen sites will be useful during experiments on the liver, during liver surgery, or after hepatic transplantation. We have compared a Clark-type flow-dependent oxygen electrode having a 3-mm-diameter cathode applied to the surface of rabbit liver to an electromagnetic flowmeter (EMF) on the portal vein. Reduction in portal flow (ranging from 4 to 100% and maintained over 2 min), correlated with reduction in electrode output (r = 0.944, P less than 0.001). Electrode output was independent of systemic arterial PO2 (ranging from 85 to 340 mm Hg) (P greater than 0.99) and thus of oxygen in inspired gases. These results indicate that this electrode gives a continuous indication of portal venous inflow when hepatic central inflow is undisturbed and may thus prove to be a useful tool in the clinical assessment of liver perfusion.

Entities:  

Mesh:

Year:  1990        PMID: 2137770     DOI: 10.1007/bf01537421

Source DB:  PubMed          Journal:  Dig Dis Sci        ISSN: 0163-2116            Impact factor:   3.199


  26 in total

1.  THE VALIDITY OF CHRONIC HEPATIC BLOOD FLOW MEASUREMENTS OBTAINED BY THE ELECTROMAGNETIC FLOW METER.

Authors:  J B PRICE; R C BRITTON; L M PETERSON; J W REILLY; A B VOORHEES
Journal:  J Surg Res       Date:  1965-07       Impact factor: 2.192

2.  Determination of the hepatic arterial blood flow and oxygen supply in man by clamping the hepatic artery during surgery.

Authors:  N TYGSTRUP; K WINKLER; K MELLEMGAARD; M ANDREASSEN
Journal:  J Clin Invest       Date:  1962-03       Impact factor: 14.808

3.  Effect of stimulation of hepatic nerves on hepatic O2 uptake and blood flow.

Authors:  W W Lautt
Journal:  Am J Physiol       Date:  1977-06

4.  A combined ultrasonic linear array scanner and pulsed Doppler velocimeter for the estimation of blood flow in the foetus and adult abdomen--II: Clinical evaluation.

Authors:  D R Griffin; M J Teague; P Tallet; K Willson; C Bilardo; L Massini; S Campbell
Journal:  Ultrasound Med Biol       Date:  1985 Jan-Feb       Impact factor: 2.998

5.  Some sources of error in measuring regional blood flow with radioactive microspheres.

Authors:  G D Buckberg; J C Luck; D B Payne; J I Hoffman; J P Archie; D E Fixler
Journal:  J Appl Physiol       Date:  1971-10       Impact factor: 3.531

6.  Tissue oximetry: an interim report.

Authors:  T K Hunt; J Rabkin; J A Jensen; K Jonsson; K von Smitten; W H Goodson
Journal:  World J Surg       Date:  1987-04       Impact factor: 3.352

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 8.  The physical principles of Doppler and spectral analysis.

Authors:  P N Burns
Journal:  J Clin Ultrasound       Date:  1987 Nov-Dec       Impact factor: 0.910

Review 9.  Blood flow and blood velocity measurement in vivo by electromagnetic induction.

Authors:  D G Wyatt
Journal:  Med Biol Eng Comput       Date:  1984-05       Impact factor: 2.602

10.  The use of surface oximetry to assess bowel viability.

Authors:  R Locke; C J Hauser; W C Shoemaker
Journal:  Arch Surg       Date:  1984-11
View more
  1 in total

1.  Endoscopic detection of ischaemia with a new probe indicates low oxygenation of gastric epithelium in portal hypertensive gastropathy.

Authors:  C Piasecki; J Chin; L Greenslade; N McIntyre; A K Burroughs; P A McCormick
Journal:  Gut       Date:  1995-05       Impact factor: 23.059

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.