| Literature DB >> 6467952 |
M J Jaeger, U H Kurzweg, M J Banner.
Abstract
We found that the transport of gases in oscillating gas columns was proportional to oscillation frequency and the square of oscillation amplitude. When these results were applied to high-frequency oscillation and high-frequency jet ventilation in dogs, alveolar ventilation was proportional to frequency and to the square of tidal volume, and inversely proportional to anatomic dead space.Entities:
Mesh:
Substances:
Year: 1984 PMID: 6467952 DOI: 10.1097/00003246-198409000-00003
Source DB: PubMed Journal: Crit Care Med ISSN: 0090-3493 Impact factor: 7.598