Literature DB >> 6439082

A fiber optic PCO2 sensor.

G G Vurek, P J Feustel, J W Severinghaus.   

Abstract

The theory, construction and performance of a catheter tip optical PCO2 probe is described. The sensor, called the Opticap, is made with plastic fiber optics. One fiber carries light to the sensitive tip which is a silicone rubber tube 0.6 mm dia. X 1.0 mm long filled with a phenol red-KHCO3 solution. Ambient PCO2 controls the pH of the solution which influences the optical transmittance of the phenol red. A second fiber carries the transmitted signal to a receiver; the resulting electrical signal is linearly related to the PCO2 over the range of 2.7 to 10.7 kPa. The probe was tested as a tissue PCO2 sensor on the cerebral cortex of the cat and as an arterial PCO2 sensor. Drift over one day's use was 0.6 KPa or less and individual probes have been used as long as 12 weeks.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6439082     DOI: 10.1007/bf02364081

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  6 in total

1.  Evaluation of a dual-function pH and PCO2 in vivo sensor.

Authors:  R L Coon; N C Lai; J P Kampine
Journal:  J Appl Physiol       Date:  1976-04       Impact factor: 3.531

2.  Hydrogen, calcium, and potassium ion-sensitive FET transducers: a preliminary report.

Authors:  S D Moss; C C Johnson; J Janata
Journal:  IEEE Trans Biomed Eng       Date:  1978-01       Impact factor: 4.538

3.  Fiber optic pH probe for physiological use.

Authors:  J I Peterson; S R Goldstein; R V Fitzgerald; D K Buckhold
Journal:  Anal Chem       Date:  1980-05       Impact factor: 6.986

4.  [The pCO2-/pO2-optode: a new probe for measurement of pCO2 or pO in fluids and gases (authors transl)].

Authors:  D W Lübbers; N Opitz
Journal:  Z Naturforsch C Biosci       Date:  1975 Jul-Aug

5.  A combined transcutaneous PO2-PCO2 electrode with electrochemical HCO3- stabilization.

Authors:  J W Severinghaus
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1981-10

Review 6.  H2 clearance measurement of blood flow: a review of technique and polarographic principles.

Authors:  W Young
Journal:  Stroke       Date:  1980 Sep-Oct       Impact factor: 7.914

  6 in total
  4 in total

Review 1.  Continuous intra-arterial blood gas monitoring.

Authors:  B Venkatesh; S P Hendry
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

2.  Sensing of carbon dioxide by a decrease in photoinduced electron transfer quenching.

Authors:  P Herman; Z Murtaza; J R Lakowicz
Journal:  Anal Biochem       Date:  1999-07-15       Impact factor: 3.365

3.  Wearable Transcutaneous CO2 Monitor Based on Miniaturized Nondispersive Infrared Sensor.

Authors:  Vishal Varun Tipparaju; Sabrina Jimena Mora; Jingjing Yu; Francis Tsow; Xiaojun Xian
Journal:  IEEE Sens J       Date:  2021-05-19       Impact factor: 4.325

Review 4.  Carbon Dioxide Sensing-Biomedical Applications to Human Subjects.

Authors:  Emmanuel Dervieux; Michaël Théron; Wilfried Uhring
Journal:  Sensors (Basel)       Date:  2021-12-28       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.