Literature DB >> 6419036

Surface dose for megavoltage photon beams outside the treatment field.

G Starkschall, F J St George, D L Zellmer.   

Abstract

Measurements made on photon beams from four different radiotherapy machines have demonstrated that skin dose several centimeters outside the boundary of a treatment field may be as much as 20% of the central axis maximum dose. This surface dose has been measured for an AECL Theratron 80, Siemens Mevatron VI, Varian Clinac 20, and CGR Sagittaire for distances up to 12 cm outside the field boundary and for depths up to the depth of maximum central axis dose. This dose has also been measured as a function of field size and of source-to-skin distance. For the lower energy photon beams, this radiation is significantly attenuated in the first 2-3 mm of tissue, while for higher energy beams, a buildup phenomenon with a dmax of 2-3 mm is observed. The magnitude of this radiation is approximately linearly dependent upon field dimension for all energies.

Mesh:

Substances:

Year:  1983        PMID: 6419036     DOI: 10.1118/1.595362

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Estimation of peripheral dose from Co60 beam in water phantom measured in Secondary Standard Dosimetry Laboratory, Pakistan.

Authors:  Muhammad Shahban; Babar Hussain; Khalid Mehmood; Shakeel Ur Rehman
Journal:  Rep Pract Oncol Radiother       Date:  2017-04-21

2.  Peripheral dose measurement in high-energy photon radiotherapy with the implementation of MOSFET.

Authors:  Vassiliki Vlachopoulou; Georgia Malatara; Harry Delis; Kiki Theodorou; Dimitrios Kardamakis; George Panayiotakis
Journal:  World J Radiol       Date:  2010-11-28

3.  Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy.

Authors:  Alexandra Bourgouin; Nicolas Varfalvy; Louis Archambault
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

4.  Testicular shield for para-aortic radiotherapy and estimation of gonad doses.

Authors:  R Ravichandran; J P Binukumar; S Kannadhasan; M H Shariff; Kamal El Ghamrawy
Journal:  J Med Phys       Date:  2008-10

5.  Skin dose during radiotherapy: a summary and general estimation technique.

Authors:  Stephen F Kry; Susan A Smith; Rita Weathers; Marilyn Stovall
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

6.  Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.

Authors:  Alexandra Bourgouin; Nicolas Varfalvy; Louis Archambault
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

7.  A simple technique to improve calculated skin dose accuracy in a commercial treatment planning system.

Authors:  Lilie Wang; Anthony J Cmelak; George X Ding
Journal:  J Appl Clin Med Phys       Date:  2018-02-06       Impact factor: 2.102

8.  Response to Re: Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy.

Authors:  Louis Archambault; Nicolas Varfalvy; Alexandra Bourgouin
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  8 in total