Detection of air embolism by transesophageal echocardiography.

H Furuya, T Suzuki, F Okumura, Y Kishi, T Uefuji.   

Abstract

In this study transesophageal echocardiography was utilized for detecting air embolism in dogs in the supine position and in patients undergoing neurosurgery in the sitting position. In dogs, the threshold dose of venous air for detection was determined using either a bolus injection or continuous infusion of air via the jugular vein for up to three minutes. The ability to detect air in the aorta also was determined by a bolus injection into the left ventricular via an arterial catheter. For venous injection of air, the threshold dose by bolus was 0.02 ml/kg. When given by infusion, air could be detected in all cases by both contrast echocardiogram and Doppler sound changes at the rate of 0.05 ml . kg-1 . min-1. When air was injected into the left ventricle, the threshold dose was 0.001 ml/kg using contrast echocardiogram. In the clinical evaluation, air was clearly demonstrated in five of six patients by transesophageal echocardiogram along with appropriate changes in Doppler sounds, pulmonary artery pressure, and end-tidal carbon dioxide concentration. Our results suggest that transesophageal echocardiography may be a more sensitive and accurate method for detecting venous air embolism than other commonly used monitors for patients undergoing neurosurgical procedures in the sitting position. This device may also be able to detect air in the aorta in patients experiencing paradoxical air embolism during surgery due to intracardiac or pulmonary shunts.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6401948     DOI: 10.1097/00000542-198302000-00004

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  20 in total

1.  Gas embolism during laparoscopy: a report of seven cases in patients with previous abdominal surgical history.

Authors:  V Cottin; B Delafosse; J P Viale
Journal:  Surg Endosc       Date:  1996-02       Impact factor: 4.584

Review 2.  Vascular Air Embolism During Bronchoscopy Procedures- Incidence, Pathophysiology, Diagnosis, Management and Outcomes.

Authors:  Venkatkiran Kanchustambham; Swetha Saladi; Kris Mehta; John Mwangi; Zafar Jamkhana; Setu Patolia
Journal:  Cureus       Date:  2017-03-09

Review 3.  [Surgery in the sitting position : anesthesiological considerations].

Authors:  A Beloiartsev; H Theilen
Journal:  Anaesthesist       Date:  2011-09       Impact factor: 1.041

Review 4.  Hemodynamic monitoring during liver transplantation: A state of the art review.

Authors:  Mona Rezai Rudnick; Lorenzo De Marchi; Jeffrey S Plotkin
Journal:  World J Hepatol       Date:  2015-06-08

5.  Paradoxical air embolism detected by transesophageal echocardiography during hepatic resection.

Authors:  Susumu Tokunaga; Tetsuo Kochi; Toshiyuki Natsume; Atsumi Anbe; Risa Hasegawa; Rika Fujii; Fumiko Ishibashi
Journal:  J Anesth       Date:  1996-06       Impact factor: 2.078

6.  Anesthesia for posterior fossa surgery in the sitting position.

Authors:  H C Tausk; R Miller
Journal:  Bull N Y Acad Med       Date:  1983-11

7.  Transnasal TOE: An alternate approach in the setting of difficult probe placement for seated spinal surgery.

Authors:  Michael G Fitzsimons; Brinda Kamdar; Johnica Eyvazzadeh; B Heidi
Journal:  Indian J Anaesth       Date:  2010-01

8.  The lounging position for posterior fossa surgery: anesthesiological considerations regarding air embolism.

Authors:  H H von Gösseln; M Samii; D Suhr; W Bini
Journal:  Childs Nerv Syst       Date:  1991-11       Impact factor: 1.475

9.  Detection of venous air embolism by continuous intraarterial oxygen monitoring.

Authors:  G Greenblott; S J Barker; K K Tremper; S Gerschultz; J L Gehrich
Journal:  J Clin Monit       Date:  1990-01

10.  Transesophageal echocardiographic study of venous air embolism following pneumomediastinum in dogs.

Authors:  W P Morris; S J Allen; A S Tonnesen; B D Butler
Journal:  Intensive Care Med       Date:  1995-10       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.