Literature DB >> 6384053

Magnetic denture retention systems: inexpensive and efficient.

B R Gillings.   

Abstract

A magnetic retention system has been used in more than 6000 complete and partial overdentures, sectional dentures and implant overdentures, with excellent clinical results and patient acceptability. For the overdenture application, decoronated, root-treated teeth are fitted with preformed or cast magnetisable alloy root elements, or 'keepers'. Following conventional denture construction, paired cobalt/samarium magnets in a special configuration are cured into the denture base so that with the denture inserted, the magnets grip the root elements with a retentive force of approximately 300 g per root. The paired magnet arrangement eliminates any external magnetic field and doubles the available retention. Magnetic retention has few of the problems encountered with other retention devices. It offers simplicity, low cost, self-adjustment, inherent stress-breaking, automatic repositioning after denture displacement, comparative freedom of lateral denture movement, reduces trauma to retained roots and eliminates the need for adjustment in service. For the sectional denture application, undesirable undercuts on the abutment teeth are used to provide passive, positive retention. The separate buccal and lingual sections are joined together by parallel pins fitting into matching tubes, assembly being maintained by magnetic attraction between a retention element in one section and a keeper in the other. Insertion and removal are more difficult than with a conventional denture but soft tissue coverage is minimal. There are no visible retainer arms and food traps are eliminated. Abutment tooth preparation is negligible, the laboratory procedures simple, and the treatment inexpensive and reversible. A clinical trial of magnetic overdenture retention in conjunction with osseointegrated titanium implants is now in progress. After 21 months acceptable clinical results have been obtained. An improved implant with an alumina core and a sintered hydroxyapatite coating is at present undergoing animal trials. Chemical bonding at the bone/implant interface is anticipated.

Entities:  

Mesh:

Year:  1984        PMID: 6384053

Source DB:  PubMed          Journal:  Int Dent J        ISSN: 0020-6539            Impact factor:   2.512


  2 in total

1.  Cytotoxic effect of indigenously fabricated dental magnets for application in prosthodontics.

Authors:  Satyabodh Shesharaj Guttal; Ramesh K Nadiger; Pravinkumar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

2.  The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture.

Authors:  Eunjee Lee; Soo-Yeon Shin
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.