Literature DB >> 6359264

Self-masking subtraction tomosynthesis.

D P Chakraborty, M V Yester, G T Barnes, A V Lakshminarayanan.   

Abstract

The authors tested the image quality and dose savings of self-masking subtraction tomosynthesis (SST), which combines digital tomosynthesis with subtraction of a blurred self-mask. High-quality images of the inner ear of a head phantom were obtained at moderate dose savings. Although they were taken with linear motion, they did not exhibit the streaking due to off-fulcrum objects that is characteristic of conventional linear tomography. SST could reduce patient dose by a factor of at least 12 in examinations of the inner ear, and the mechanical aspects can be implemented with moderate modifications of existing instrumentation.

Entities:  

Mesh:

Year:  1984        PMID: 6359264     DOI: 10.1148/radiology.150.1.6359264

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Intravenous pyelogram artefacts unique to digital tomosynthesis reconstruction.

Authors:  B K Rowberry; A Galea
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

2.  Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach.

Authors:  Yue-Houng Hu; Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

Review 3.  Tomosynthesis imaging: at a translational crossroads.

Authors:  James T Dobbins
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  Wavelet denoising for quantum noise removal in chest digital tomosynthesis.

Authors:  Tsutomu Gomi; Masahiro Nakajima; Tokuo Umeda
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-04-20       Impact factor: 2.924

5.  Improving image quality for digital breast tomosynthesis: an automated detection and diffusion-based method for metal artifact reduction.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Lubomir M Hadjiiski; Ravi K Samala
Journal:  Phys Med Biol       Date:  2017-09-15       Impact factor: 3.609

6.  An in vitro evaluation of cone-beam breast CT methods.

Authors:  Kai Zeng; Laurie L Fajardo; Simon Kao; Edmund A Franken; Jeong Mi Park; Zhenxue Jing; Er-Wei Bai; Ge Wang
Journal:  J Xray Sci Technol       Date:  2008-10-01       Impact factor: 1.535

7.  Chest tomosynthesis: technical principles and clinical update.

Authors:  James T Dobbins; H Page McAdams
Journal:  Eur J Radiol       Date:  2009-07-18       Impact factor: 3.528

  7 in total