Preliminary experience with Brown-Roberts-Wells (BRW) computerized tomography stereotaxic guidance system.

M P Heilbrun, T S Roberts, M L Apuzzo, T H Wells, J K Sabshin.   

Abstract

The production model of the Brown-Roberts-Wells (BRW) computerized tomography (CT) stereotaxic guidance system is described. Hardware and software modifications to the original prototype now allow the system to be used independently of the CT scanner after an initial scan with the localizing components fixed to the skull. The system is simple and efficient, can be used universally with all CT scanners, and includes a phantom simulator system for target verification. Preliminary experience with 74 patients at two institutions is described. It is concluded that CT stereotaxic guidance systems will become important tools in the neurosurgical armamentarium, as they allow accurate approach to any target identifiable on the CT scan.

Entities:  

Mesh:

Year:  1983        PMID: 6345727     DOI: 10.3171/jns.1983.59.2.0217

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  21 in total

1.  A new model for non-invasive, reproducible fixation of a stereotaxic frame using an orthodontic resin plate. Technical note.

Authors:  S Carini; E Calcagno; P Tortori-Donati; L Andreussi
Journal:  Acta Neurochir (Wien)       Date:  1992       Impact factor: 2.216

2.  Neurosurgery with craniotomy and CT stereotactic guidance in the treatment of intracerebral space-occupying lesions.

Authors:  J F Hirsch; C S Rose; A Pierre-Kahn; D Renier; E Hoppe-Hirsch
Journal:  Childs Nerv Syst       Date:  1990-09       Impact factor: 1.475

3.  A new ultrasound-guided brain biopsy technique through a burr hole. Technical note.

Authors:  Y Tsutsumi; Y Andoh; J Sakaguchi
Journal:  Acta Neurochir (Wien)       Date:  1989       Impact factor: 2.216

4.  Neurosurgery-important advances in clinical medicine: computed tomographic guided stereotaxis of the brain.

Authors:  M L Apuzzo
Journal:  West J Med       Date:  1984-05

5.  New head fixation for the Riechert stereotaxic system. Technical note.

Authors:  C B Ostertag
Journal:  Acta Neurochir (Wien)       Date:  1988       Impact factor: 2.216

Review 6.  The Origin and History of the N-Localizer for Stereotactic Neurosurgery.

Authors:  Russell A Brown; James A Nelson
Journal:  Cureus       Date:  2015-09-14

7.  Proceedings of the 113th meeting of the Society of British Neurological Surgeons and the joint meeting with the British Society of Neuroradiologists. Glasgow, 22-24 September 1988. Abstracts.

Authors: 
Journal:  J Neurol Neurosurg Psychiatry       Date:  1989-07       Impact factor: 10.154

8.  Measurement of tissue impedence in conjunction with computed tomography-guided stereotaxic biopsies.

Authors:  D E Bullard; T T Makachinas
Journal:  J Neurol Neurosurg Psychiatry       Date:  1987-01       Impact factor: 10.154

9.  Importance of image-guided stereotactic biopsy to confirm diagnosis in an oncological setting.

Authors:  E Arbit; J H Galicich
Journal:  Ann Surg Oncol       Date:  1994-09       Impact factor: 5.344

Review 10.  The Invention and Early History of the N-Localizer for Stereotactic Neurosurgery.

Authors:  Russell A Brown; James A Nelson
Journal:  Cureus       Date:  2016-06-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.