Literature DB >> 1456099

A new model for non-invasive, reproducible fixation of a stereotaxic frame using an orthodontic resin plate. Technical note.

S Carini1, E Calcagno, P Tortori-Donati, L Andreussi.   

Abstract

The authors describe a new method for reproducible, non-invasive fixation of a stereotaxic localizing frame. A localizing system similar to that of Brown-Roberts-Wells for MR can be fixed at the base of the facial skeleton to the upper dental arch by an orthodontic resin plate. Results of trials with CT scan, advantages and disadvantages are discussed. The new fixture could be employed in open surgery and in fractionated radiotherapy.

Mesh:

Substances:

Year:  1992        PMID: 1456099     DOI: 10.1007/bf01401301

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  16 in total

1.  Localization of brain tumors with a simple scalp-mounted fiducial device. Technical note.

Authors:  H Hirschberg
Journal:  J Neurosurg       Date:  1989-02       Impact factor: 5.115

2.  Evolution of contemporary instrumentation for computer-assisted stereotactic surgery.

Authors:  P J Kelly; S J Goerss; B A Kall
Journal:  Surg Neurol       Date:  1988-09

3.  Preoperative localization of intracranial lesions on MR.

Authors:  G Krol; J Galicich; E Arbit; G Sze; J Amster
Journal:  AJNR Am J Neuroradiol       Date:  1988 May-Jun       Impact factor: 3.825

4.  A simple and inexpensive method for CT-guided stereotaxy.

Authors:  K Wester; O Sortland; E Hauglie-Hanssen
Journal:  Neuroradiology       Date:  1981-01       Impact factor: 2.804

5.  Computed tomography/guided stereotactic surgery: conception and development of a new stereotactic methodology.

Authors:  J H Perry; A E Rosenbaum; L D Lunsford; C A Swink; D S Zorub
Journal:  Neurosurgery       Date:  1980-10       Impact factor: 4.654

6.  Preliminary experience with Brown-Roberts-Wells (BRW) computerized tomography stereotaxic guidance system.

Authors:  M P Heilbrun; T S Roberts; M L Apuzzo; T H Wells; J K Sabshin
Journal:  J Neurosurg       Date:  1983-08       Impact factor: 5.115

7.  Stereotaxic frame and computer software for CT-directed neurosurgical localization.

Authors:  R A Brown; T S Roberts; A G Osborn
Journal:  Invest Radiol       Date:  1980 Jul-Aug       Impact factor: 6.016

8.  A critical evaluation of two methods of head fixation.

Authors:  D P Kingsley; M Bergström; B M Berggren
Journal:  Neuroradiology       Date:  1980       Impact factor: 2.804

9.  Head fixation system for integration of radiodiagnostic and therapeutic procedures.

Authors:  T Greitz; M Bergström; J Boëthius; D Kingsley; T Ribbe
Journal:  Neuroradiology       Date:  1980       Impact factor: 2.804

10.  Localization of vertex lesions on cranial computed tomography.

Authors:  S H Lee; T Villafana
Journal:  Radiology       Date:  1980-02       Impact factor: 11.105

View more
  3 in total

Review 1.  A review of the automated detection of change in serial imaging studies of the brain.

Authors:  Julia Patriarche; Bradley Erickson
Journal:  J Digit Imaging       Date:  2004-06-29       Impact factor: 4.056

2.  On "Evaluation of the Contribution of CAS in Combination with the Subcranial/Subfrontal Approach in Anterior Skull Base Surgery" (Skull Base 2001;11:59-76).

Authors: 
Journal:  Skull Base       Date:  2002-02

3.  Halo ring supporting the Brown-Roberts-Wells stereotactic frame for fractionated radiotherapy.

Authors:  S Carini; G Scielzo; F Grillo Ruggieri; F Bistolfi; M Ravegnani; L Andreussi
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.