Literature DB >> 6342033

Intra-arterial digital subtraction angiography of the head and neck.

M A Weinstein, W A Pavlicek, M T Modic, P M Duchesneau.   

Abstract

Intra-arterial digital subtraction angiography (IA DSA) was compared with conventional film/screen angiography in 70 patients with suspected atherosclerotic disease or intracranial disease. It was found that, although the contrast detectability of IA DSA was superior to that of conventional angiography, its spatial resolution was not as great. In all 70 cases, however, the spatial resolution of IA DSA was satisfactory for diagnosis, and it is concluded that the increased spatial resolution of conventional angiography should be necessary only in rare circumstances. The main disadvantage of IA DSA is the smaller field size, and it has several advantages over conventional film/screen angiography: (a) it is safer, since less contrast material is needed to visualize large vessels; (b) costs are lower since the magnetic recording tape and hard copies result in a savings of between $45 and $140 per examination; and (c) there is less need for darkroom personnel and film storage.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6342033     DOI: 10.1148/radiology.147.3.6342033

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  Selective cerebral intraarterial DSA. Complication rate and control of risk factors.

Authors:  U Grzyska; J Freitag; H Zeumer
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

2.  Evaluation of the carotid artery bifurcation: comparison of magnetic resonance angiography and digital subtraction arch aortography.

Authors:  D K Kido; J B Barsotti; L Z Rice; B M Rothenberg; R J Panzer; S P Souza; C L Dumoulin
Journal:  Neuroradiology       Date:  1991       Impact factor: 2.804

3.  Intra-arterial digital subtraction angiography in the evaluation of peripheral vascular trauma.

Authors:  C A Howard; E R Thal; H C Redman; P Gibson
Journal:  Ann Surg       Date:  1989-07       Impact factor: 12.969

4.  Neuroradiological applications of a new system of stereoscopic biplane digital subtraction angiography.

Authors:  K Hasuo; A Mizushima; S Matsumoto; F Mihara; T Yoshiura; Y Umezu; K Masuda
Journal:  Neuroradiology       Date:  1996-07       Impact factor: 2.804

5.  Evaluation of the cerebral vasculature by intraarterial DSA--with emphasis on in vivo resolution.

Authors:  M Takahashi; H Bussaka; N Nakagawa
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

6.  Intracranial magnetic resonance angiography.

Authors:  P M Ruggieri; T J Masaryk; J S Ross; M T Modic
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Jan-Feb       Impact factor: 2.740

7.  Intra-arterial DSA: early experience with a 1024(2) matrix.

Authors:  W M Kelly; M Brant-Zawadzki; M A Schardt; C L Carrol
Journal:  Neuroradiology       Date:  1985       Impact factor: 2.804

8.  Comparison of digital subtraction arteriography and conventional film screen subtraction arteriography for neuroradiology.

Authors:  R A Zimmerman; R I Grossman; H I Goldberg; R Lynch; R Levine; L Samuel
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

  8 in total