Literature DB >> 6340452

Beat-to-beat left ventricular performance in atrial fibrillation: radionuclide assessment with the computerized nuclear probe.

J Schneider, H J Berger, M J Sands, A B Lachman, B L Zaret.   

Abstract

There is wide beat-to-beat variability in cycle length and left ventricular performance in patients with atrial fibrillation. In this study, left ventricular ejection fraction and relative left ventricular volumes were evaluated on a beat-to-beat basis with the computerized nuclear probe, an instrument with sufficiently high sensitivity to allow continuous evaluation of the radionuclide time-activity curve. Of 18 patients with atrial fibrillation, 5 had mitral stenosis, 6 had mitral regurgitation, and 7 had coronary artery disease. Fifty consecutive beats were analyzed in each patient. The mean left ventricular ejection fraction ranged from 17 to 51%. There was substantial beat-to-beat variation in cycle length and left ventricular ejection fraction in all patients, including those with marked left ventricular dysfunction. In 14 patients who also underwent multiple gated cardiac blood pool imaging, there was an excellent correlation between mean ejection fraction derived from the nuclear probe and gated ejection fraction obtained by gamma camera imaging (r = 0.90). Based on beat-to-beat analysis, left ventricular function was dependent on relative end-diastolic volume and multiple preceding cycle lengths, but not preceding end-systolic volumes. This study demonstrates that a single value for left ventricular ejection fraction does not adequately characterize left ventricular function in patients with atrial fibrillation. Furthermore, both the mean beat-to-beat and the gated ejection fraction may underestimate left ventricular performance at rest in such patients.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6340452     DOI: 10.1016/0002-9149(83)90367-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  A historical perspective on measurement of ventricular function with scintigraphic techniques: Part II--Ventricular function with gated techniques for blood pool and perfusion imaging.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

2.  Has LVEF changed beyond chance? Limits of agreement of radiotracer-derived LVEF.

Authors:  Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

3.  Changes in left ventricular function during exercise and their relation to ST segment changes in patients with angina.

Authors:  M J O'Hara; R I Jones; A Lahiri; E B Raftery
Journal:  Br Heart J       Date:  1986-02

4.  Gated cardiac blood pool studies in atrial fibrillation: role of cycle length windowing.

Authors:  J W Wallis; J E Juni; L Wu
Journal:  Eur J Nucl Med       Date:  1991

5.  Left ventricular beat to beat performance in atrial fibrillation: dependence on contractility, preload, and afterload.

Authors:  H J Muntinga; A T Gosselink; P K Blanksma; P J De Kam; E E Van Der Wall; H J Crijns
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

6.  Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation.

Authors:  Kambiz Shahgaldi; Aristomenis Manouras; Anna Abrahamsson; Petri Gudmundsson; Lars-Ake Brodin; Reidar Winter
Journal:  Cardiovasc Ultrasound       Date:  2010-10-05       Impact factor: 2.062

7.  Left Atrial Size and Function in a Canine Model of Chronic Atrial Fibrillation and Heart Failure.

Authors:  Adam Goldberg; Kenya Kusunose; Salima Qamruddin; L Leonardo Rodriguez; Todor N Mazgalev; Brian P Griffin; David R Van Wagoner; Youhua Zhang; Zoran B Popović
Journal:  PLoS One       Date:  2016-01-15       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.