Literature DB >> 6336846

The application of matched filtering to x-ray exposure reduction in digital subtraction angiography: clinical results.

S J Riederer, D R Enzmann, A L Hall, N J Pelc, W T Djang.   

Abstract

This new digital fluorography processing method of matched filtering generates a set of images that have been acquired at continuous video-frame rates (30 per second) over the temporal extent of the bolus (10 seconds), and it combines them to produce the equivalent of a single digital subtraction angiography (DSA) image. Because of the extensive temporal averaging used, the method can provide substantial x-ray exposure reduction per run as compared with conventional techniques for an equivalent signal-to-noise ratio in the final image. The matched filtering technique was compared with conventional pulsed (one per second) DSA images of both extracranial and intracranial arteries, and the results are presented. Matched filtered images provided image quality that was equivalent to that of conventional DSA images at about one-fourth the patient exposure per run for both carotid artery and cerebral vessel studies. Despite long integration times, patient motion irretrievably corrupted image quality in only two of five carotid artery studies and in none of three intracranial studies. Compensation for patient motion is demonstrated, and additional applications and limitations of the technique are discussed.

Entities:  

Mesh:

Year:  1983        PMID: 6336846     DOI: 10.1148/radiology.146.2.6336846

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Cardiac applications of digital subtraction angiography.

Authors:  R A Vogel; G B Mancini; E R Bates
Journal:  Int J Card Imaging       Date:  1985

2.  Intravenous digital subtraction angiography of orbital and ocular circulation. A preliminary experimental study.

Authors:  A W Fryczkowski; D J Delany; R L Peiffer; B S Grimson; B C Brenton
Journal:  Int Ophthalmol       Date:  1985-09       Impact factor: 2.031

Review 3.  Left ventricular imaging by digital subtraction angiography.

Authors:  R A Vogel
Journal:  Int J Card Imaging       Date:  1988

4.  DSA evaluation of the STA-MCA bypass.

Authors:  B D Lewis; E Kwan; D R Enzmann
Journal:  Neuroradiology       Date:  1984       Impact factor: 2.804

5.  Clinical application of hybrid subtraction digital angiography: preliminary results.

Authors:  D F Guthaner; W R Brody; B D Lewis; G S Keyes; B F Belanger
Journal:  Cardiovasc Intervent Radiol       Date:  1983       Impact factor: 2.740

6.  Image data acquisition, processing, storage and display.

Authors:  R A Kruger
Journal:  Cardiovasc Intervent Radiol       Date:  1983       Impact factor: 2.740

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.