Literature DB >> 6325493

Human rotavirus detection by counterimmunoelectrophoresis versus enzyme immunoassay and electron microscopy after direct ultracentrifugation.

G W Hammond, G S Ahluwalia, B Klisko, P R Hazelton.   

Abstract

The sensitivity of the counterimmunoelectrophoresis test with NCDV, Wa, and SA-11 rotavirus antisera was 60, 60, and 67%, respectively. The counterimmunoelectrophoresis specificity was greater than 99%, but the low sensitivity is a limiting feature of this test as a first-line immunodiagnostic test for rotavirus detection.

Entities:  

Mesh:

Year:  1984        PMID: 6325493      PMCID: PMC271085          DOI: 10.1128/jcm.19.3.439-441.1984

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

1.  Counter-immunoelectro-osmophoresis for the detection of infantile gastroenteritis virus (orbi-group) antigen and antibody.

Authors:  P J Middleton; M Petric; C M Hewitt; M T Szymanski; J S Tam
Journal:  J Clin Pathol       Date:  1976-03       Impact factor: 3.411

2.  Antigenic characterization of human and animal rotaviruses by immune adherence hemagglutination assay (IAHA): evidence for distinctness of IAHA and neutralization antigens.

Authors:  A Z Kapikian; W L Cline; H B Greenberg; R G Wyatt; A R Kalica; C E Banks; H D James; J Flores; R M Chanock
Journal:  Infect Immun       Date:  1981-08       Impact factor: 3.441

3.  Definition of human rotavirus serotypes by plaque reduction assay.

Authors:  R G Wyatt; H B Greenberg; W D James; A L Pittman; A R Kalica; J Flores; R M Chanock; A Z Kapikian
Journal:  Infect Immun       Date:  1982-07       Impact factor: 3.441

4.  Comparison of Counterimmunoelectrophoresis and electron microscopy for laboratory diagnosis of human reovirus-like agent-associated infantile gastroenteritis.

Authors:  L Spence; M Fauvel; R Petro; S Bloch
Journal:  J Clin Microbiol       Date:  1977-02       Impact factor: 5.948

5.  Letter: Test for reovirus-like agent.

Authors:  L Spence; M Fauvel; S Bouchard; L Babiuk
Journal:  Lancet       Date:  1975-08-16       Impact factor: 79.321

6.  Comparison of an enzyme immunoassay with electron microscopic procedures for detecting rotavirus.

Authors:  A S Rubenstein; M F Miller
Journal:  J Clin Microbiol       Date:  1982-05       Impact factor: 5.948

7.  Rapid diagnosis of rotavirus infections: comparison of electron microscopy and immunoelectroosmophoresis for the detection of rotavirus in human infantile gastroenteritis.

Authors:  P C Grauballe; J Genner; A Meyling; A Hornsleth
Journal:  J Gen Virol       Date:  1977-05       Impact factor: 3.891

8.  Optimized enzyme-linked immunosorbent assay for detection of human and bovine rotavirus in stools: Comparison with electron-microscopy, immunoelectro-osmophoresis, and fluorescent antibody techniques.

Authors:  P C Grauballe; B F Vestergaard; A Meyling; J Genner
Journal:  J Med Virol       Date:  1981       Impact factor: 2.327

9.  Comparison of immunosorbent electron microscopy, enzyme immunoassay and counterimmunoelectrophoresis for detection of human rotavirus in stools.

Authors:  G Obert; R Gloeckler; J Burckard; M H van Regenmortel
Journal:  J Virol Methods       Date:  1981-09       Impact factor: 2.014

10.  Improved detection of viruses by electron microscopy after direct ultracentrifuge preparation of specimens.

Authors:  G W Hammond; P R Hazelton; I Chuang; B Klisko
Journal:  J Clin Microbiol       Date:  1981-08       Impact factor: 5.948

View more
  5 in total

1.  Detection of verotoxin in stool specimens.

Authors:  A C Maniar; T Williams; C M Anand; G W Hammond
Journal:  J Clin Microbiol       Date:  1990-01       Impact factor: 5.948

2.  Epidemiology of rotavirus electropherotypes determined by a simplified diagnostic technique with RNA analysis.

Authors:  K T Dolan; E M Twist; P Horton-Slight; C Forrer; L M Bell; S A Plotkin; H F Clark
Journal:  J Clin Microbiol       Date:  1985-05       Impact factor: 5.948

3.  Latex immunoassay for rapid detection of rotavirus.

Authors:  J H Hughes; A V Tuomari; D R Mann; V V Hamparian
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

4.  Detection of rotavirus in faecal specimens with a monoclonal antibody enzyme-linked immunosorbent assay: comparison with polyclonal antibody enzyme immuno-assays and a latex agglutination test.

Authors:  M Sneyers; C Thiriart; C Bruyns; A F Lambert; C Collignon; A Schwers; P Coppe; H Antoine; J D Franssen; J Urbain
Journal:  Comp Immunol Microbiol Infect Dis       Date:  1989       Impact factor: 2.268

Review 5.  Electron microscopy for rapid diagnosis of infectious agents in emergent situations.

Authors:  Paul R Hazelton; Hans R Gelderblom
Journal:  Emerg Infect Dis       Date:  2003-03       Impact factor: 6.883

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.