Literature DB >> 627501

Reliability of noninvlasive methods for measuring cardiac function in exercise.

L A Wolfe, D A Cunningham, G M Davis, P A Rechnitzer.   

Abstract

Externally recorded systolic time intervals (STI's), indirect (CO2 re-breathing) cardiac output, and auscultatory blood pressures were measured during upright bicycle ergometer work in 20 healthy men, aged 24-56 yr. The subjects were studied on 2 separate days at steady-state work loads chosen to represent light (mean heart rate (HR) = 96 beats.min-1), moderate (HR = 118 beats.min-1) and heavy (HR = 147 beats.min-1) exercise. In addition to determinations of cardiac output, systolic time intervals, and blood pressure, the individual's mean systolic ejection rate (stroke volume/left ventricular ejection time) was calculated as a measure of left ventricular function. In general, heart-rate-corrected STI's were found to be reliable and reproducible. Reliability coefficients for total electromechanical systole and left ventricular ejection time ranged from 0.93 to 0.96 while those for the preejection period and its subcomponents were between 0.63 and 0.88. The reliability of cardiac output, stroke volume, mean systolic ejection rate, and systolic blood pressure was also considered to be acceptable but tended to be higher during moderate and heavy work (r = 0.85-0.95) compared to light exercise (r = 0.60-0.83).

Entities:  

Mesh:

Year:  1978        PMID: 627501     DOI: 10.1152/jappl.1978.44.1.55

Source DB:  PubMed          Journal:  J Appl Physiol Respir Environ Exerc Physiol        ISSN: 0161-7567


  6 in total

1.  Cardiac responses to lower body negative pressure and dynamic leg exercise.

Authors:  O Eiken; H Bjurstedt
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1985

2.  A comprehensive cardiac exercise stress processor for environmental health effects studies.

Authors:  M L Petrovick; P N Kizakevich; R W Stacy; E D Haak
Journal:  J Med Syst       Date:  1980       Impact factor: 4.460

3.  Impedance-derived cardiac indices in supine and upright exercise.

Authors:  J J Smith; M Muzi; J A Barney; J Ceschi; J Hayes; T J Ebert
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

Review 4.  Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: Conventional techniques.

Authors:  D E Warburton; M J Haykowsky; H A Quinney; D P Humen; K K Teo
Journal:  Sports Med       Date:  1999-01       Impact factor: 11.136

5.  Cardiovascular response to interval and continuous training in women.

Authors:  D A Cunningham; D McCrimmon; L F Vlach
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1979-07-02

6.  Reproducibility of the exponential rise technique of CO(2) rebreathing for measuring P(v)CO(2) and C(v)CO(2 )to non-invasively estimate cardiac output during incremental, maximal treadmill exercise.

Authors:  W Todd Cade; Sharmila R Nabar; Randall E Keyser
Journal:  Eur J Appl Physiol       Date:  2003-12-03       Impact factor: 3.078

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.