Literature DB >> 6270189

Difference in antibody reactivity between complement fixation and immune adherence hemagglutination tests with virus antigens.

S Inouye, S Matsuno, R Kono.   

Abstract

Complement-fixing (CF) immunoglobulin M antibody to infantile gastroenteritis virus (a rotavirus) did not show the reactivity of immune adherence hemagglutination (IAHA). Early immunoglobulin G CF antibody produced both in patients and in guinea pigs experimentally infected with Japanese encephalitis virus (a flavivirus) had weak reactivity in IAHA test. However, late antibody showed higher titers by IAHA than by CF. These results suggested that early antibodies with lower affinity are inefficient in the IAHA reaction. The implications of this study are: (i) a low ratio of IAHA/CF antibody titers in a serum suggests a recent rotavirus infection; (ii) the IAHA reaction is more type specific than the CF reaction for identifying the serotype of antigenically cross-reacting viruses with hyperimmune sera.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 6270189      PMCID: PMC271948          DOI: 10.1128/jcm.14.3.241-246.1981

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  30 in total

1.  A new complement function: solubilization of antigen-antibody aggregates.

Authors:  G W Miller; V Nussenzweig
Journal:  Proc Natl Acad Sci U S A       Date:  1975-02       Impact factor: 11.205

2.  Detection of antibody to Varicella-Zoster virus by immune adherence hemagglutination.

Authors:  A A Gershon; Z G Kalter; S Steinberg; W J Kuhns
Journal:  Proc Soc Exp Biol Med       Date:  1976-04

3.  Specific immune adherence assay for human hepatitis A antibody application to diagnostic and epidemiologic investigations.

Authors:  W J Miller; P J Provost; W J McAleer; O L Ittensohn; V M Villarejos; M R Hilleman
Journal:  Proc Soc Exp Biol Med       Date:  1975-05

4.  Viral hepatitis, type A. Identification by specific complement fixation and immune adherence tests.

Authors:  S Krugman; H Friedman; C Lattimer
Journal:  N Engl J Med       Date:  1975-05-29       Impact factor: 91.245

5.  Detection of a new virus by electron microscopy of faecal extracts from children with acute gastroenteritis.

Authors:  R F Bishop; G P Davidson; I H Holmes; B J Ruck
Journal:  Lancet       Date:  1974-02-02       Impact factor: 79.321

6.  Immune adherence hemagglutination test as a new sensitive method for titration of animal virus antigens and antibodies.

Authors:  M Ito; I Tagaya
Journal:  Jpn J Med Sci Biol       Date:  1966-06

7.  Detection of Australia antigen by means of immune adherence haemagglutination test.

Authors:  M Mayumi; K Okochi; K Nishioka
Journal:  Vox Sang       Date:  1971-02       Impact factor: 2.144

8.  Letter: Mercaptoethanol-sensitive antibody to reovirus-like agents in acute epidemic gastroenteritis.

Authors:  T Konno; A Imai; H Suzuki; N Ishida
Journal:  Lancet       Date:  1975-12-27       Impact factor: 79.321

9.  Standardized viral hemagglutination and hemagglutination-inhibition tests. I. Standardization of erythrocyte suspensions.

Authors:  J C Hierholzer; M T Suggs
Journal:  Appl Microbiol       Date:  1969-11

10.  Studies on the mechanism of solubilization of immune precipitates by serum.

Authors:  J Czop; V Nussenzweig
Journal:  J Exp Med       Date:  1976-03-01       Impact factor: 14.307

View more
  8 in total

1.  Single-serum diagnosis of rubella by combined use of the hemagglutination inhibition and passive hemagglutination tests.

Authors:  S Inouye; K Satoh; T Tajima
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

2.  Changes in antibody avidity after virus infections: detection by an immunosorbent assay in which a mild protein-denaturing agent is employed.

Authors:  S Inouye; A Hasegawa; S Matsuno; S Katow
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

3.  Immune adherence hemagglutination test for detection of antibody to respiratory syncytial virus. Brief report.

Authors:  N Kobayashi; Y Noguchi; M Kojima; M Matumoto
Journal:  Arch Virol       Date:  1984       Impact factor: 2.574

4.  Assay of human rotavirus antibody by immune adherence hemagglutination with a cultivable human rotavirus as antigen.

Authors:  S Matsuno; S Inouye; A Hasegawa; R Kono
Journal:  J Clin Microbiol       Date:  1982-01       Impact factor: 5.948

5.  Rapid test for detection of rabies antibodies in human serum.

Authors:  D B Budzko; L J Charamella; D Jelinek; G R Anderson
Journal:  J Clin Microbiol       Date:  1983-03       Impact factor: 5.948

6.  Infectivity titration of hemorrhagic fever with renal syndrome virus: use of immune adherence hemagglutination for detection of virus growth.

Authors:  Y Matsuura; K Sugiyama; C Morita; S Morikawa; S Shiga; T Komatsu; Y Akao; T Kitamura
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

7.  Isolation of human rotaviruses in primary cultures of monkey kidney cells.

Authors:  A Hasegawa; S Matsuno; S Inouye; R Kono; Y Tsurukubo; A Mukoyama; Y Saito
Journal:  J Clin Microbiol       Date:  1982-08       Impact factor: 5.948

8.  Epidemiological studies of hemorrhagic fever with renal syndrome (HFRS) related virus infection among urban rats in Hokkaido, Japan.

Authors:  J Arikawa; I Takashima; N Hashimoto; K Takahashi; K Yagi; K Hattori
Journal:  Arch Virol       Date:  1986       Impact factor: 2.574

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.