| Literature DB >> 6257758 |
A D Pronovost, A Baumgarten, G D Hsiung.
Abstract
A chemiluminescent enzyme-linked immunosorbent assay (CELISA) was developed for detecting human immunoglobulin G and herpes simplex viral antigen. A comparison of CELISA with a conventional absorptiometric detection system showed that CELISA was 100 times more sensitive than absorptiometry for the measurement of human immunglobulin G. Similarly, CELISA detected as few as 40 plaque-forming units of herpes simplex virus in contrast to 2,500 plaque-forming units detected by absorptiometry. Of 18 specimens which were positive for herpes simplex virus type 1 by isolation in tissue culture, 15 (83%) were detected by CELISA within a few hours; in certain cases, several days were necessary for detection of virus by isolation techniques.Entities:
Mesh:
Substances:
Year: 1981 PMID: 6257758 PMCID: PMC273730 DOI: 10.1128/jcm.13.1.97-101.1981
Source DB: PubMed Journal: J Clin Microbiol ISSN: 0095-1137 Impact factor: 5.948