Adult human valve dimensions and their surgical significance.

S Westaby, R B Karp, E H Blackstone, S P Bishop.   

Abstract

After cardiac valve replacement, some patients may show little improvement in functional status, in part because their prosthesis is restrictive. Guidelines were sought for valve replacement from measurements of valve circumference and calculated circularized orifice area in 160 postmortem hearts from adults with and without congestive cardiac failure. Multivariate analysis was used to relate valve area to age, sex, height, body surface area and cardiac failure. Only sex and cardiac failure were significantly related to valve area. Body surface area and other variables were poorly related to valve area. The mean (+/- standard deviation) circularized orifice area for adult male (M) and female (F) heart valves in the absence of cardiac failure were: Aortic, M 4.81 +/- 1.30, F 3.73 +/- 0.98; pulmonary, M 4.88 +/- 1.25, F 4.32 +/- 1.03; mitral, M 8.70 +/- 2.08, F 6.94 +/- 1.41; and tricuspid, M 11.9 +/- 2.72, F 9.33 +/- 2.02. In cardiac failure, atrioventricular valves enlarge (p less than 0.004). Guided by these dimensions, the surgeon can aim to insert a prosthesis of appropriate size. Comparison of these sizes with the manufacturer's calculated area for current prostheses shows that most mechanical valves and bioprostheses are potentially restrictive at rest. Improved prosthestic design, valve repair whenever possible, and anular enlargement procedures would be required to eliminate this size disparity.

Entities:  

Mesh:

Year:  1984        PMID: 6229998     DOI: 10.1016/0002-9149(84)90029-8

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  9 in total

1.  Aortic valve annular dimension in Indian population.

Authors:  Hannah Sugirthabai Rajila Rajendran; Sudha Seshayyan; Ashok Victor; Gangadevi Rajapandian
Journal:  J Clin Diagn Res       Date:  2013-09-10

2.  Left ventricular outflow tract obstruction due to anomalous mitral valve: successful mitral valve replacement in a four month old infant.

Authors:  P Morais; S Westaby; K A Hallidie-Smith
Journal:  Br Heart J       Date:  1986-10

3.  Aortic valve replacement with 31- and 33-mm mechanical prostheses: early results.

Authors:  Gaurav Gupta; Ambuj Roy; A Sampath Kumar
Journal:  Tex Heart Inst J       Date:  2004

4.  Does transcatheter aortic valve alignment matter?

Authors:  Jacob Andrew Salmonsmith; Andrea Ducci; Gaetano Burriesci
Journal:  Open Heart       Date:  2019-11-21

Review 5.  Echocardiographic Imaging Challenges in Obesity: Guideline Recommendations and Limitations of Adjusting to Body Size.

Authors:  Maninder Singh; Anuradha Sethi; Abhishek K Mishra; Navin K Subrayappa; Dwight D Stapleton; Patricia A Pellikka
Journal:  J Am Heart Assoc       Date:  2020-01-09       Impact factor: 5.501

6.  Cardiac Transplantation in Dermatomyositis: A case report and literature review.

Authors:  Sangmee Bae; Negar Khanlou; Christina Charles-Schoeman
Journal:  Hum Pathol (N Y)       Date:  2017-03-31

7.  The development of a flexible heart model for simulation-based training.

Authors:  Jelle Man; Jos Maessen; Peyman Sardari Nia
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-01-22

8.  A Multiphysics Biventricular Cardiac Model: Simulations With a Left-Ventricular Assist Device.

Authors:  Azam Ahmad Bakir; Amr Al Abed; Michael C Stevens; Nigel H Lovell; Socrates Dokos
Journal:  Front Physiol       Date:  2018-09-11       Impact factor: 4.566

Review 9.  Materials and manufacturing perspectives in engineering heart valves: a review.

Authors:  F Oveissi; S Naficy; A Lee; D S Winlaw; F Dehghani
Journal:  Mater Today Bio       Date:  2019-12-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.