Literature DB >> 6220490

Measurement of carotid blood flow in man and its clinical application.

S Uematsu, A Yang, T J Preziosi, R Kouba, T J Toung.   

Abstract

With the use of a new ultrasonic volume flow meter (VFM), over 8000 measurements of common carotid blood flow were made in 120 normal control subjects and 550 patients with various neurological disease. The accuracy of the flow meter in measuring blood flow on an experimental model ranged from 93 to 97%. In normal subjects, common carotid blood flow varies with age. It increased from newborn to age 20 and gradually decreased thereafter. In normal healthy subjects, the flow varies within +/- 6.7% (2SD) at one sitting (intrasession) and +/- 21.2% (2SD) from week to week (intersession study). Carotid blood flow varies linearly with PaCO2 and increased markedly in response to endotracheal intubation. In healthy adults, the flow ratio between the two common carotid arteries is 1.07 +/- 0.052. This ratio increases in patients with transient ischemic attacks to 1.28 +/- 0.23 (p less than 0.05) and in patients with intracranial space occupying lesions to 1.46 +/- 0.39, (p less than 0.01). In 26 consecutive cases of carotid endarterectomies, the preoperative common carotid blood volume flow was 5.1 +/- 1.0 cc/sec. All cases preoperatively had at least 30% stenosis and ranged from 30 to 100% stenosis. The carotid blood volume was significantly increased post-operatively (p less than 0.001). The overall accuracy in detecting carotid and cerebral arterial disease is 89% with sensitivity of 96% and the specificity of 71%. Our clinical experience indicates that this device is not only a valuable noninvasive diagnostic tool for evaluation of carotid disease but also appears to be useful in assessing cerebral blood flow.

Entities:  

Mesh:

Year:  1983        PMID: 6220490     DOI: 10.1161/01.str.14.2.256

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  21 in total

1.  Blood flow velocity waveform in the common carotid artery and its analysis in elderly subjects.

Authors:  I Nagatomo; M Nomaguchi; K Matsumoto
Journal:  Clin Auton Res       Date:  1992-06       Impact factor: 4.435

2.  Calcitonin gene-related peptide (CGRP) causes redistribution of blood flow in humans.

Authors:  K Jäger; R Muench; H Seifert; C Beglinger; A Bollinger; J A Fischer
Journal:  Eur J Clin Pharmacol       Date:  1990       Impact factor: 2.953

3.  Reproducibility of Doppler blood flow velocity waveform measurements: study on variability within and between day and during haemodynamic intervention in normal subjects.

Authors:  G H Rimoy; N K Bhaskar; P C Rubin
Journal:  Eur J Clin Pharmacol       Date:  1991       Impact factor: 2.953

4.  Cerebral blood flow velocities during orthostasis and physical exercise.

Authors:  H Bode
Journal:  Eur J Pediatr       Date:  1991-08       Impact factor: 3.183

5.  Fast 4D flow MRI intracranial segmentation and quantification in tortuous arteries.

Authors:  Eric Schrauben; Anders Wåhlin; Khalid Ambarki; Erik Spaak; Jan Malm; Oliver Wieben; Anders Eklund
Journal:  J Magn Reson Imaging       Date:  2015-04-02       Impact factor: 4.813

6.  Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium.

Authors:  K I Jo; S R Kim; J H Choi; K H Kim; P Jeon
Journal:  Neuroradiology       Date:  2015-08-21       Impact factor: 2.804

7.  Doppler ultrasound measurement of cerebral blood flow in healthy pregnant women.

Authors:  Akihito Nakai; Hiroko Yamada; Atsuko Oya; Tatsuo Koshino; Tsutomu Araki
Journal:  J Med Ultrason (2001)       Date:  2002-12       Impact factor: 1.314

8.  Intraobserver reproducibility and interobserver agreement of ultrasonic flowmetry using the velocity profile color doppler method in the common carotid artery.

Authors:  Nobuyuki Taniguchi; Ryuuichi Takano; Kouichi Itoh; Syukuko Kaneko; Akira Onoguchi; Yi Wang; Tomoyuki Kuwata; Kouichiro Shigeta; Tomoko Ono
Journal:  J Med Ultrason (2001)       Date:  2003-03       Impact factor: 1.314

9.  A mathematical study of human intracranial hydrodynamics. Part 2--Simulation of clinical tests.

Authors:  M Ursino
Journal:  Ann Biomed Eng       Date:  1988       Impact factor: 3.934

10.  Difference in blood flow volume of the common carotid artery between vascular and non-vascular dementia detected by colour duplex sonography.

Authors:  T Hamada; M Takita; H Kawano; A Noh-tomi; M Okayama
Journal:  J Neurol       Date:  1993       Impact factor: 4.849

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.