A phase-locked echo tracking system for recording arterial diameter changes in vivo.

D E Hokanson, D J Mozersky, D S Sumner, D E Strandness.   

Abstract

Mesh:

Year:  1972        PMID: 5038866     DOI: 10.1152/jappl.1972.32.5.728

Source DB:  PubMed          Journal:  J Appl Physiol        ISSN: 0021-8987            Impact factor:   3.531


× No keyword cloud information.
  14 in total

1.  Equations for estimating muscle fiber stress in the left ventricular wall.

Authors:  S I Rabben; F Irgens; B Angelsen
Journal:  Heart Vessels       Date:  1999       Impact factor: 2.037

2.  The use of nitroprusside to characterize aortic pressure-diameter relationships.

Authors:  J J Ferguson; S Momomura; P Sahagian; M J Miller; R G McKay
Journal:  Tex Heart Inst J       Date:  1989

3.  Ultrasonic transit-time system for arterial diameter measurement.

Authors:  C D Bertram
Journal:  Med Biol Eng Comput       Date:  1977-09       Impact factor: 2.602

4.  Noninvasive measurement of aortic pressure waveform by ultrasound.

Authors:  H Watanabe; M Kawai; T Sibata; M Hara; H Furuhata; S Mochizuki
Journal:  Heart Vessels       Date:  1998       Impact factor: 2.037

5.  Feasibility of dual Doppler velocity measurements to estimate volume pulsations of an arterial segment.

Authors:  Craig J Hartley; Anilkumar K Reddy; Sridhar Madala; Mark L Entman; George E Taffet
Journal:  Ultrasound Med Biol       Date:  2010-07       Impact factor: 2.998

6.  The evolution of morphologic and biomechanical changes in reversed and in-situ vein grafts.

Authors:  R P Cambria; J Megerman; D C Brewster; D F Warnock; J Hasson; W M Abbott
Journal:  Ann Surg       Date:  1987-02       Impact factor: 12.969

7.  Spectrum analysis in ultrasonic Doppler blood flow monitoring: experience in its application to deeply situated vessels.

Authors:  C J Hodson; F A Duck
Journal:  Can Med Assoc J       Date:  1973-06-02       Impact factor: 8.262

8.  Noninvasive measurement of arterial diameters in humans using ultrasound echoes with prefiltered waveforms.

Authors:  M Eriksen
Journal:  Med Biol Eng Comput       Date:  1987-03       Impact factor: 2.602

9.  Continuous measurement of aortic radius change in vivo with an intra-aortic ultrasonic catheter.

Authors:  D J Hughes; N E Fearnot; C F Babbs; J D Bourland; L A Geddes; R Eggelton
Journal:  Med Biol Eng Comput       Date:  1985-05       Impact factor: 2.602

10.  New phase-lock tracking instrument for foetal breathing monitoring.

Authors:  I Rapoport; A J Cousin
Journal:  Med Biol Eng Comput       Date:  1982-01       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.