Evaluation of laminar flow microbiological safety cabinets.

R H Staat, J W Beakley.   

Abstract

The microbiological control efficiency of two class 100 laminar down-flow hoods was determined by using aerosols of Bacillus subtilis var. niger spores. The first unit challenged utilized a slanted eyelid to partially enclose the front work opening. This hood showed nearly perfect control of ambient organisms in the work area. It also gave a 10(6) or greater drop in the number of organisms passing out of the exhaust system. However, when the interior work area of the hood was challenged, significant numbers of spores penetrated the air barrier and escaped into the ambient air. A redesigned laminar flow hood was built incorporating a vertical eyelid and a reduced opening to the work area. This hood showed the same excellent characteristics for controlling ambient contamination. Exhaust system leakage was also extremely low. Air barrier efficiency for the newer hood was increased with lower amounts of spore penetration into the ambient air.

Entities:  

Mesh:

Substances:

Year:  1968        PMID: 4971719      PMCID: PMC547688          DOI: 10.1128/am.16.10.1478-1482.1968

Source DB:  PubMed          Journal:  Appl Microbiol        ISSN: 0003-6919


  2 in total

1.  New sampler for the collection, sizing, and enumeration of viable airborne particles.

Authors:  A A ANDERSEN
Journal:  J Bacteriol       Date:  1958-11       Impact factor: 3.490

2.  Microbiological studies conducted in a vertical laminar airflow surgery.

Authors:  J J McDade; J G Whitcomb; E W Rypka; W J Whitfield; C M Franklin
Journal:  JAMA       Date:  1968-01-08       Impact factor: 56.272

  2 in total
  6 in total

1.  Influence of crossdrafts on the performance of a biological safety cabinet.

Authors:  B W Rake
Journal:  Appl Environ Microbiol       Date:  1978-08       Impact factor: 4.792

2.  Validation of cross-contamination control in biological safety cabinet for biotech/pharmaceutical manufacturing process.

Authors:  Shih-Cheng Hu; Angus Shiue; Jin-Xin Tu; Han-Yang Liu; Rong-Ben Chiu
Journal:  Environ Sci Pollut Res Int       Date:  2015-08-11       Impact factor: 4.223

3.  Class II (laminar flow) biological safety cabinet.

Authors:  S W Newsom
Journal:  J Clin Pathol       Date:  1979-05       Impact factor: 3.411

4.  Modified laminar flow biological safety cabinet.

Authors:  G J McGarrity; L L Coriell
Journal:  Appl Microbiol       Date:  1974-10

5.  Bacteriological testing of a modified laminar flow microbiological safety cabinet.

Authors:  P J Heidt
Journal:  Antonie Van Leeuwenhoek       Date:  1982       Impact factor: 2.271

6.  Prevention of airborne contamination and cross-contamination in germ-free mice by laminar flow.

Authors:  D van der Waaij; A H Andreas
Journal:  J Hyg (Lond)       Date:  1971-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.