Literature DB >> 455822

The effect of hemodialysis on endogenous middle molecules in uremic patients.

H Asaba, P Fürst, R Oulés, V Yahiel, L Zimmerman, J Bergström.   

Abstract

Uremic plasma and dialysis fluid were separated by high speed gel filtration followed by gradient elution ion exchange chromatography into several UV-absorbing fractions containing middle molecules (MM) (7a, b, c, etc.), which were quantitated by integrating the peak areas of the chromatograms. Dialyzer clearance of MM was determined in vivo for two dialyzers, Gambro Optima and RP-6, but no difference could be found in spite of far better in vitro MM clearance of RP-6 than of Gambro Optima. Nor was there any difference in post-dialysis decrease in MM between the two dialyzers, or between them and two dialyzers with larger surface areas (Gambro Major and Dow HK-5). In 45 determinations of MM in blood obtained before and after dialysis, using different dialyzers, the mean decrease in MM was significantly larger than for creatinine, suggesting a much smaller distribution volume immediately available for exchange. Ultrafiltration without dialysis in 7 patients induced a significant decrease in plasma MM (7a, b, c, and g) in spite of stable osmolality, urea, creatinine, and sodium concentrations in plasma, suggesting that the reduction in body water affected the net production rate of these MM. In 5 studies, using RP-6 and a 75 l recirculating dialyzate, a rapid post-dialysis rebound was observed for MM in plasma, sometimes followed by a secondary decrease in plasma concentration. The volume of distribution of dialyzed MM, assessed from pre- and post-plasma concentrations and concentrations in the dialyzate, appeared to be much smaller than for urea and creatinine. In a stable dialysis population of 17 patients, significant negative correlations were found between pre-dialysis plasma concentrations of some MM (7a, 7b, 7f, 7g) and dialysis index or endogenous renal creatinine clearance. No such correlations were found for peaks 7c and 7d. The good correlation between 7b and dialysis index (r = 0.73) suggests that plasma determination of 7b may be used as a measure of the efficiency of MM removal.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 455822

Source DB:  PubMed          Journal:  Clin Nephrol        ISSN: 0301-0430            Impact factor:   0.975


  3 in total

1.  On-line monitoring of solutes in dialysate using wavelength-dependent absorption of ultraviolet radiation.

Authors:  I Fridolin; L G Lindberg
Journal:  Med Biol Eng Comput       Date:  2003-05       Impact factor: 2.602

2.  Middle molecular substances in acute renal failure.

Authors:  M Mydlík; V Spustová; R Dzúrik; K Derzsiová
Journal:  Int Urol Nephrol       Date:  1982       Impact factor: 2.370

3.  Isα-endorphin an uremic toxin?α-Endorphin isolated from filtrate of uremic patients with carbohydrate intolerance.

Authors:  T Abiko; H Sekino
Journal:  Amino Acids       Date:  1993-02       Impact factor: 3.520

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.