Literature DB >> 441339

R-wave synchronized blood-pool imaging.

S G Sorensen, G W Hamilton, D L Williams, J L Ritchie.   

Abstract

Three methods for determining the left ventricular ejection fraction (EF) from R-wave synchronized blood-pool images were compared to contrast angiography; the reproducibility of these methods was established in 51 patients. The EF was systematically underestimated by the fixed region-of-interest (ROI) method compared to the two methods that used varying ROI's which track the left ventricular boundary. All methods correlated reasonably well with angiography and were highly reproducible. Use of varying ROI's resulted in EF values that were essentially identical to those determined by angiography. Resolution-recovery image processing appeared to improve reproducibility when varying ROI's were used.

Entities:  

Mesh:

Year:  1979        PMID: 441339     DOI: 10.1148/131.2.473

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Factor analysis of multigated cardiac blood pool scintigram for the measurement of left ventricular ejection fraction.

Authors:  N Honda; K Machida; T Mamiya; T Takahashi; T Takishima; T Kamano; N Hasegawa; M Hashimoto; K Ohno; M Hosoba
Journal:  Ann Nucl Med       Date:  1989-07       Impact factor: 2.668

2.  Quantitative aspect of two-factor analysis applied to radionuclide gated cardiac studies.

Authors:  K Murase; T Mochizuki; K Hamamoto
Journal:  Eur J Nucl Med       Date:  1988

3.  Automated determination of the right ventricular ejection fraction by digital processing of 81mKr scintigrams.

Authors:  R Elfner; R Vaknine; W H Knapp; H Tillmanns; W J Lorenz
Journal:  Eur J Nucl Med       Date:  1986

4.  Reproducibility of ejection fraction measurements by gated equilibrium blood pool scintigraphy.

Authors:  G A Heidendal; P D Bezemer; P A Koopman; W den Hollander; G J Teule; E E van der Wall; A Hasman
Journal:  Eur J Nucl Med       Date:  1983

5.  Quantitative analysis of left ventricular function from equilibrium gated blood pool scintigrams: an overview of computer methods.

Authors:  J H Reiber
Journal:  Eur J Nucl Med       Date:  1985

6.  Comparison of three semiautomatic methods for determination of left ventricular ejection fraction from gated cardiac blood pool images.

Authors:  J Bingham; R Okada; K McKusick; C Boucher; E Tarolli; N Alpert; W Strauss
Journal:  Eur J Nucl Med       Date:  1985
  6 in total