Literature DB >> 422334

Method of measuring aqueous humor flow and corneal endothelial permeability using a fluorophotometry nomogram.

R L Coakes, R F Brubaker.   

Abstract

A new method of measuring aqueous humor flow and corneal endothelial permeability to fluorescein using a fluorophotometry nomogram is described. This method is compared to four other methods, two of which have been described previously. All five methods were carried out simultaneously in a group of 20 normal human subjects. All methods give closely comparable results in most of the eyes tested. A tabular comparison of the results of the nomographic method and the published results of other investigators, which are in good agreement, is given. The relative advantages and disadvantages of the nomographic technique are discussed.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 422334

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  18 in total

1.  Study on the aqueous humor flow measured by fluorophotometry after argon laser trabeculoplasty.

Authors:  D Aliseda Pérez; P C Fernández Vila; P Beneyto Martin
Journal:  Int Ophthalmol       Date:  1992-09       Impact factor: 2.031

2.  A fluorophotometric study on the aqueous humor dynamics in primary open angle glaucoma.

Authors:  P Beneyto Martin; P C Fernández Vila; T M Pérez Martinez; D Aliseda Peréz
Journal:  Int Ophthalmol       Date:  1992-09       Impact factor: 2.031

3.  Comparative study of three methods of evaluation of the corneal endothelium in pseudophakic patients: fluorophotometry, specular microscopy and pachymetry.

Authors:  P Beneyto; R Gutierrez; T M Pérez
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-10       Impact factor: 3.117

4.  Five-year follow-up of endothelial cell function of pseudophakic patients with anterior segment fluorophotometry.

Authors:  C Ohrloff; M Spitznas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1987       Impact factor: 3.117

5.  Reference values for normal corneal transfer coefficient (Kc) as tested with the Fluorotron-Master.

Authors:  C Ohrloff; M Spitznas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1987       Impact factor: 3.117

6.  Diffusion of fluorescein in the corneal stroma.

Authors:  S Nagataki; F Brubaker; A Grotte
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1985       Impact factor: 3.117

7.  The ciliary vasculature and its perturbation with drugs and surgery.

Authors:  E M Van Buskirk
Journal:  Trans Am Ophthalmol Soc       Date:  1988

8.  Corneal endothelial permeability and aqueous humor flow using a standard protocol.

Authors:  J A van Best; M Diestelhorst; E Leite; S Fantaguzzi; R Schalnus
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1995-09       Impact factor: 3.117

9.  Morphologic and functional evaluation of the endothelium of transplanted human corneas.

Authors:  W M Bourne
Journal:  Trans Am Ophthalmol Soc       Date:  1983

10.  Effects of adrenergic drugs on aqueous humour dynamics in the normal human eye. I. Salbutamol.

Authors:  R L Coakes; P B Siah
Journal:  Br J Ophthalmol       Date:  1984-06       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.