Literature DB >> 418685

A simple photogrammetric method of measuring anterior chamber volume.

S B Johnson, R L Coakes, R F Brubaker.   

Abstract

We devised a convenient method of measuring anterior chamber volume in man. Photographs of the anterior chamber were taken with a Zeiss photographic slit lamp with a Polaroid attachment, and measured with a specially constructed transparent scale. Using this method, the standard deviation of individual measurements of volume on different occasions in a given eye was 8 microliter. The standard deviation of the differences between right and left eyes of normal subjects was 10 microliter. The volume of the anterior chamber measured in 78 eyes of 39 normal subjects (mean age, 28 years; range, 19 to 56 years) was found to be 209 +/- 37 microliter (mean +/- SD). We observed a small negative correlation between the age of the subject and the volume of the anterior chamber.

Entities:  

Mesh:

Year:  1978        PMID: 418685     DOI: 10.1016/s0002-9394(14)75243-2

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  15 in total

1.  Circadian variation of aqueous humor dynamics in older healthy adults.

Authors:  Cherie B Nau; Mehrdad Malihi; Jay W McLaren; David O Hodge; Arthur J Sit
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-11-15       Impact factor: 4.799

2.  Effect of topical phenylephrine on the permeability of the blood-aqueous barrier in man.

Authors:  M Araie; M Mori; T Oshika
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1992       Impact factor: 3.117

3.  Circadian variation of aqueous dynamics in young healthy adults.

Authors:  Arthur J Sit; Cherie B Nau; Jay W McLaren; Douglas H Johnson; David Hodge
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-04       Impact factor: 4.799

4.  Functional measurements on the enlarged endothelial cells of corneal transplants.

Authors:  W M Bourne
Journal:  Trans Am Ophthalmol Soc       Date:  1995

5.  Measurement method of the anterior chamber volume by image analysis.

Authors:  T Kondo; M Miura; M Imamichi
Journal:  Br J Ophthalmol       Date:  1986-09       Impact factor: 4.638

6.  Effects of the encircling procedure on the aqueous flow rate in retinal detachment eyes: a fluorometric study.

Authors:  M Araie; Y Sugiura; K Minota; K Akazawa
Journal:  Br J Ophthalmol       Date:  1987-07       Impact factor: 4.638

7.  The ciliary vasculature and its perturbation with drugs and surgery.

Authors:  E M Van Buskirk
Journal:  Trans Am Ophthalmol Soc       Date:  1988

8.  Asymmetric pigment dispersion syndrome.

Authors:  M I Kaiser-Kupfer; C Kupfer; L McCain
Journal:  Trans Am Ophthalmol Soc       Date:  1983

9.  Measurements of axial and peripheral anterior chamber depth: accuracy of a photographic method.

Authors:  R A Hitchings; J Romano; P Clark
Journal:  Br J Ophthalmol       Date:  1984-03       Impact factor: 4.638

10.  Morphologic and functional evaluation of the endothelium of transplanted human corneas.

Authors:  W M Bourne
Journal:  Trans Am Ophthalmol Soc       Date:  1983
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.