Literature DB >> 3756123

Measurement method of the anterior chamber volume by image analysis.

T Kondo, M Miura, M Imamichi.   

Abstract

A new computerised method of measurement of the anterior chamber in the human eye is described. Photographs of the anterior chamber were taken with a Zeiss slit-lamp 75-SL and converted from an optical image into a true image by computer with a digitiser. We obtained data on both the anterior chamber volume and also the anterior chamber depth, peripheral anterior chamber volume, the diameter of the anterior chamber, and the degree of the iridocorneal angle. These data were simultaneously displayed several seconds after in-put by the digitiser. In mensuration by digitiser on three occasions from a single photograph of a given eye the mean deviation rate was about 0.7%, and the mean deviation rate of 10 successive exposures of one eye was 3.5%. By this image analysis technique an accurate profile of the anterior chamber is displayed of the pupil margin, iris-root insertion, and central anteroposterior pupillary axis. These data help us to understand the mechanism of primary angle-closure glaucoma.

Entities:  

Mesh:

Year:  1986        PMID: 3756123      PMCID: PMC1040796          DOI: 10.1136/bjo.70.9.668

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  8 in total

1.  A SIMPLE PHOTOGRAPHIC METHOD OF MEASURING THE VOLUME OF THE ANTERIOR CHAMBER.

Authors:  R F JONES; D M MAURICE
Journal:  Exp Eye Res       Date:  1963-07       Impact factor: 3.467

2.  A simple photogrammetric method of measuring anterior chamber volume.

Authors:  S B Johnson; R L Coakes; R F Brubaker
Journal:  Am J Ophthalmol       Date:  1978-04       Impact factor: 5.258

3.  Quantitative slit-image photography of the anterior chamber.

Authors:  N Brown
Journal:  Trans Ophthalmol Soc U K       Date:  1973

4.  Ocular dimensions in the heredity of angle-closure glaucoma.

Authors:  A Tomlinson; D A Leighton
Journal:  Br J Ophthalmol       Date:  1973-07       Impact factor: 4.638

5.  Mechanics of pupil block.

Authors:  R Mapstone
Journal:  Br J Ophthalmol       Date:  1968-01       Impact factor: 4.638

6.  The fluorescein distribution volume of the anterior chamber.

Authors:  S B Johnson; J A Passmore; R F Brubaker
Journal:  Invest Ophthalmol Vis Sci       Date:  1977-07       Impact factor: 4.799

7.  A simple geometrical method of measuring anterior chamber dimensions.

Authors:  S Nagataki; D A Lee; M Iri
Journal:  Invest Ophthalmol Vis Sci       Date:  1984-10       Impact factor: 4.799

8.  Volume and depth of the anterior chamber in the normal aging human eye.

Authors:  S T Fontana; R F Brubaker
Journal:  Arch Ophthalmol       Date:  1980-10
  8 in total
  3 in total

1.  Quantitative evaluation of changes in anterior segment biometry by peripheral laser iridotomy using newly developed scanning peripheral anterior chamber depth analyser.

Authors:  K Kashiwagi; K Abe; S Tsukahara
Journal:  Br J Ophthalmol       Date:  2004-08       Impact factor: 4.638

2.  Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs.

Authors:  Seong Joon Ahn; Hye Kyoung Hong; Young Mi Na; Sang Jun Park; Jeeyun Ahn; Jaeseong Oh; Jae Yong Chung; Kyu Hyung Park; Se Joon Woo
Journal:  J Vis Exp       Date:  2016-07-23       Impact factor: 1.355

3.  A method of measuring pupil-blocking force in the human eye.

Authors:  T Kondo; M Miura
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1987       Impact factor: 3.117

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.