Literature DB >> 4086424

Comparative measurements of potassium and chloride with ion-sensitive microelectrodes and x-ray microanalysis in cultured skeletal muscle fibers.

H Acker, F Pietruschka, K Zierold.   

Abstract

Data of the intracellular electrolyte concentration of potassium and chloride in cultured muscle cells measured by x-ray analysis were compared by using the different activity coefficients with intracellular potassium and chloride activities measured with double-barrelled microelectrodes. By using an activity coefficient of 0.6, 95% of the potassium microelectrode measurements are in accordance with the x-ray analysis values, in spite of a scattering of the values. Membrane potential and intracellular potassium values are linearly related. x-ray analysis and ion-sensitive microelectrodes measured the cytoplasmic chloride in the same range. Taking into account known activity coefficients, an error of 25% must be assumed with the intracellular chloride measurements. However, x-ray analysis and ion-sensitive microelectrode investigations are reliable tools to study intracellular potassium and chloride changes, which play an important role in membrane characteristics.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4086424     DOI: 10.1007/BF02620913

Source DB:  PubMed          Journal:  In Vitro Cell Dev Biol        ISSN: 0883-8364


  6 in total

1.  Potassium transport and content during G1 and S phase following serum stimulation of 3T3 cells.

Authors:  J T Tupper; F Zorgniotti; B Mills
Journal:  J Cell Physiol       Date:  1977-06       Impact factor: 6.384

Review 2.  Intracellular ionic activity measurements in nerve and muscle.

Authors:  J L Walker; H M Brown
Journal:  Physiol Rev       Date:  1977-10       Impact factor: 37.312

3.  Penetration of substances into tumor tissue: a methodological study with microelectrodes and cellular spheroids.

Authors:  T Nederman; H Acker; J Carlsson
Journal:  In Vitro       Date:  1983-06

4.  The element distribution in ultrathin cryosections of cultivated fibroblast cells.

Authors:  K Zierold; D Schäfer; F Pietruschka
Journal:  Histochemistry       Date:  1984

5.  Cell puncturing with a step motor driven manipulator with simultaneous measurement of displacement.

Authors:  U Sonnhof; R Förderer; W Schneider; H Kettenmann
Journal:  Pflugers Arch       Date:  1982-01       Impact factor: 3.657

6.  Double-barrell ion-sensitive microelectrodes with extra thin tip diameters for intracellular measurements.

Authors:  E Dufau; H Acker; D Sylvester
Journal:  Med Prog Technol       Date:  1980-04
  6 in total
  2 in total

1.  Controlled release of biologically active silver from nanosilver surfaces.

Authors:  Jingyu Liu; David A Sonshine; Saira Shervani; Robert H Hurt
Journal:  ACS Nano       Date:  2010-10-22       Impact factor: 15.881

2.  Primary liver cell cultures grown on gas permeable membrane as source for the collection of primary bile.

Authors:  E Petzinger; W Föllmann; H Acker; J Hentschel; K Zierold; R K Kinne
Journal:  In Vitro Cell Dev Biol       Date:  1988-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.