Literature DB >> 4077868

Tensile strength of bovine trabecular bone.

S J Kaplan, W C Hayes, J L Stone, G S Beaupré.   

Abstract

Data on the tensile and compressive properties of trabecular bone are needed to define input parameters and failure criteria for modeling total joint replacements. To help resolve differences in reports comparing tensile and compressive properties of trabecular bone, we have developed new methods, based on porous foam technology, for tensile testing of fresh/frozen trabecular bone specimens. Using bovine trabecular bone from an isotropic region from the proximal humerus as a model material, we measured ultimate strengths in tension and compression for two groups of 24 specimens each. The average ultimate strength in tension was 7.6 +/- 2.2 (95% C.I.) MPa and in compression was 12.4 +/- 3.2 MPa. This difference was statistically significant (p = 0.013) and was not related to density differences between the test groups (p = 0.28). Strength was related by a power-law function of the local apparent density, but, even accounting for density influences, isotropic bovine trabecular bone exhibits significantly lower strengths in tension than in compression.

Entities:  

Mesh:

Year:  1985        PMID: 4077868     DOI: 10.1016/0021-9290(85)90027-2

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Oxidized nickel-titanium foams for bone reconstructions: chemical and mechanical characterization.

Authors:  Maite Barrabés; Alexandra Michiardi; Conrado Aparicio; Pablo Sevilla; Josep A Planell; Francisco Javier Gil
Journal:  J Mater Sci Mater Med       Date:  2007-07-10       Impact factor: 3.896

2.  A novel hypothesis for the formation of conoidal projectile wounds in sandwich bones.

Authors:  John M Rickman; James Shackel
Journal:  Int J Legal Med       Date:  2018-10-18       Impact factor: 2.686

3.  Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study.

Authors:  Rajesh Ghosh
Journal:  J Orthop       Date:  2016-03-29

4.  A comparative finite-element analysis of bone failure and load transfer of osseointegrated prostheses fixations.

Authors:  P K Tomaszewski; N Verdonschot; S K Bulstra; G J Verkerke
Journal:  Ann Biomed Eng       Date:  2010-03-23       Impact factor: 3.934

5.  The Segond fracture occurs at the site of lowest sub-entheseal trabecular bone volume fraction on the tibial plateau.

Authors:  William Mullins; Gavin E Jarvis; Daniel Oluboyede; Linda Skingle; Ken Poole; Tom Turmezei; Cecilia Brassett
Journal:  J Anat       Date:  2020-08-08       Impact factor: 2.610

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.