Literature DB >> 4046993

Energy and angular distributions of photons from medical linear accelerators.

R Mohan, C Chui, L Lidofsky.   

Abstract

For accurate three-dimensional treatment planning, new models of dose calculations are being developed which require the knowledge of the energy spectra and angular distributions of the photons incident on the surface of the patient. Knowledge of the spectra is also useful in other applications, including the design of filters and beam modifying devices and determination of factors to convert ionization chamber measurements to dose. We have used Monte Carlo code (EGS) to compute photon spectra for a number of different linear accelerators. Both the target and the flattening filter have been accurately modeled. We find the mean photon energy to have a value lower than the generally perceived value of one-third the maximum energy. As expected, the spectra become softer as the distance from the central axis increases. Verification of the spectra is performed by computing dose distributions and half-value layers in water using the calculated spectra and comparing the results with measured data. We also examined the angular distributions of photons incident on the surface of the phantom. In currently used models of dose computations, it is assumed that the angular distribution of photons with respect to fan lines emanating from the source is negligible. Although the angular spread of photons with respect to the incident direction has been found to be small, its contribution to the diffuseness of the beam boundaries is significant.

Entities:  

Mesh:

Year:  1985        PMID: 4046993     DOI: 10.1118/1.595680

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

1.  Interface software for DOSXYZnrc Monte Carlo dose evaluation on a commercial radiation treatment planning system.

Authors:  Etsuo Kunieda; Hossain M Deloar; Shunji Takagi; Koichi Sato; Takatsugu Kawase; Hidetoshi Saitoh; Kimiaki Saito; Osamu Sato; Graham Sorell; Atsushi Kubo
Journal:  Radiat Med       Date:  2007-07-27

2.  Monte Carlo simulation for Neptun 10 PC medical linear accelerator and calculations of output factor for electron beam.

Authors:  Mohammad Taghi Bahreyni Toossi; Mehdi Momennezhad; Seyed Mohammad Hashemi
Journal:  Rep Pract Oncol Radiother       Date:  2012-03-06

3.  Dosimetric properties and commissioning of cone-beam CT image beam line with a carbon target.

Authors:  Y Dzierma; F G Nuesken; N P Licht; C Ruebe
Journal:  Strahlenther Onkol       Date:  2013-05-30       Impact factor: 3.621

4.  Estimation of focal and extra-focal radiation profiles based on Gaussian modeling in medical linear accelerators.

Authors:  Shigeo Anai; Hidetaka Arimura; Katsumasa Nakamura; Fujio Araki; Takaomi Matsuki; Hideki Yoshikawa; Satoshi Yoshidome; Yoshiyuki Shioyama; Hiroshi Honda; Nobuo Ikeda
Journal:  Radiol Phys Technol       Date:  2011-03-24

5.  Monte Carlo-based energy response studies of diode dosimeters in radiotherapy photon beams.

Authors:  C Arun; T Palani Selvam; Verma Dinkar; Prabhat Munshi; Manjit Singh Kalra
Journal:  Radiol Phys Technol       Date:  2012-11-20

6.  [Organizational models of inpatient emergency and acute care].

Authors:  A Kaltwasser; C Dodt
Journal:  Med Klin Intensivmed Notfmed       Date:  2014-10       Impact factor: 0.840

7.  Evaluation of the incident directional dependence of radiochromic film by use of Monte Carlo simulation and measurement.

Authors:  Yuki Yuasa; Shinji Kawamura; Takehiro Shiinoki; Takuya Uehara; Masahiro Koike; Ryuji Kanzaki; Hideki Hanazawa; Shotaro Takahashi; Keiko Shibuya
Journal:  Radiol Phys Technol       Date:  2016-03-24

8.  Adaptation, Commissioning, and Evaluation of a 3D Treatment Planning System for High-Resolution Small-Animal Irradiation.

Authors:  Jeho Jeong; Qing Chen; Robert Febo; Jie Yang; Hai Pham; Jian-Ping Xiong; Pat B Zanzonico; Joseph O Deasy; John L Humm; Gig S Mageras
Journal:  Technol Cancer Res Treat       Date:  2015-05-06

9.  Dosimetry of interface region near closed air cavities for Co-60, 6 MV and 15 MV photon beams using Monte Carlo simulations.

Authors:  Chandra P Joshi; Johnson Darko; P B Vidyasagar; L John Schreiner
Journal:  J Med Phys       Date:  2010-04

10.  Monte carlo simulation of bony heterogeneity effects on dose profile for small irradiation field in radiotherapy.

Authors:  Simone C Cardoso; Victor Gabriel L Alves; Luiz Antonio R da Rosa; Luciana T Campos; Delano V S Batista; Alessandro Facure
Journal:  PLoS One       Date:  2010-05-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.