Literature DB >> 4032106

Repeatability of phasic muscle activity: performance of surface and intramuscular wire electrodes in gait analysis.

M P Kadaba, M E Wootten, J Gainey, G V Cochran.   

Abstract

Repeatability is an important consideration for gait analysis data that are being used as an adjunct to clinical decision making. An index of repeatability may be based on a statistical criterion (variance ratio) that reflects similarity of wave forms over a number of identical cycles. The purpose of this study was to use the variance ratio to assess the repeatability of phasic muscle activity recorded with surface and bipolar intramuscular wire electrodes during gait on 10 normal subjects. Variance ratios were calculated using rectified and smoothed electromyographic data recorded simultaneously from the two types of electrodes. Three measures of repeatability (reproducibility, reliability, and constancy--defined as the cycle-to-cycle, run-to-run, and day-to-day repeatability of phasic muscle activity) were used to compare the performance of the two electrode techniques. Results show that the reproducibility and reliability were better for surface electrodes than for intramuscular wire electrodes, and constancy was good for surface electrodes and poor for intramuscular wire electrodes. Repeatability improved with increasing smoothing window lengths but was better for surface electrodes than wire electrodes, irrespective of the smoothing window. This study indicates that surface electrode data represent a more consistent measure of activity of superficial muscles, if comparisons are to be made between gait data from different test days.

Entities:  

Mesh:

Year:  1985        PMID: 4032106     DOI: 10.1002/jor.1100030312

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  15 in total

1.  [The value of instrumented gait analysis in infantile cerebral palsy].

Authors:  L Döderlein; S Wolf
Journal:  Orthopade       Date:  2004-10       Impact factor: 1.087

2.  The functional anatomy of tensor fasciae latae and gluteus medius and minimus.

Authors:  F Gottschalk; S Kourosh; B Leveau
Journal:  J Anat       Date:  1989-10       Impact factor: 2.610

3.  Repeatability of electromyography recordings and muscle synergies during gait among children with cerebral palsy.

Authors:  Katherine M Steele; Meghan E Munger; Keshia M Peters; Benjamin R Shuman; Michael H Schwartz
Journal:  Gait Posture       Date:  2018-10-22       Impact factor: 2.840

4.  Repeatability of surface EMG during gait in children.

Authors:  Kevin P Granata; Darin A Padua; Mark F Abel
Journal:  Gait Posture       Date:  2005-01-08       Impact factor: 2.840

5.  The influence of external perturbations on running kinematics and muscle activity before and after accommodation.

Authors:  Anita Haudum; Jürgen Birklbauer; Erich Müller
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

6.  Effects of walking in a force field for varying durations on aftereffects and on next day performance.

Authors:  Karine Fortin; Andreanne Blanchette; Bradford J McFadyen; Laurent J Bouyer
Journal:  Exp Brain Res       Date:  2009-08-26       Impact factor: 1.972

7.  Electromyographic signals during gait: criteria for envelope filtering and number of strides.

Authors:  R Shiavi; C Frigo; A Pedotti
Journal:  Med Biol Eng Comput       Date:  1998-03       Impact factor: 2.602

8.  Neuromuscular activation patterns during treadmill walking after space flight.

Authors:  C S Layne; P V McDonald; J J Bloomberg
Journal:  Exp Brain Res       Date:  1997-01       Impact factor: 1.972

9.  Popliteus function in ACL-deficient patients.

Authors:  M J Weresh; R H Gabel; R A Brand; D S Tearse
Journal:  Iowa Orthop J       Date:  1994

10.  Reliability study of tibialis posterior and selected leg muscle EMG and multi-segment foot kinematics in rheumatoid arthritis associated pes planovalgus.

Authors:  Ruth Barn; Daniel Rafferty; Deborah E Turner; James Woodburn
Journal:  Gait Posture       Date:  2012-06-20       Impact factor: 2.840

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.