In a retrospective review of eighty-two intertrochanteric fractures (twenty-nine stable and fifty-three unstable) in seventy-nine elderly, debilitated patients with associated advanced osteoporosis (Grade III or less by the system of Singh et al.), fifty-six were available for follow-up: twenty-eight that had been treated at the University of Illinois with an approximately anatomical reduction and compression-screw fixation and twenty-eight (in twenty-seven patients) that had been treated at the University of Chicago with an approximately anatomical reduction, compression-screw fixation, and adjunctive methylmethacrylate bone cement in the head-neck fragment. Follow-up analysis after an average of thirty-four months for the group that had augmentation with cement and an average of twenty-six months for the uncemented group showed that for the eighteen stable fractures that could be followed the rates of complications of fixation were the same in the two groups, while for the thirty-eight unstable comminuted fractures that were followed the rate of complications of fixation was lower when adjunctive methylmethacrylate cement was used. Among the unstable fractures, one failure (in twenty-one fractures) in the cement-augmented group and ten failures (in seventeen fractures) in the uncemented group were due to failure of fixation (p less than 0.01). For reasons that are not clear, when the thirty-two patients with a healed fracture who could be evaluated for function were rated using the Iowa hip score, the nineteen who were treated with adjunctive cement had significantly lower scores than did the thirteen who were treated without cement (76 +/- 16.5 compared with 92 +/- 12.1, p less than 0.01).

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4030829

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  14 in total

1.  Biomechanical analysis of the dynamic hip screw in the treatment of intertrochanteric fractures.

Authors:  C C Wu; C H Shih
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

2.  Fixation of basicervical and related fractures.

Authors:  Elsayed Ibraheem Elsayed Massoud
Journal:  Int Orthop       Date:  2009-05-28       Impact factor: 3.075

Review 3.  Treatment strategies for proximal femur fractures in osteoporotic patients.

Authors:  Felix Bonnaire; Henry Zenker; Christoph Lill; Andreas T Weber; Berend Linke
Journal:  Osteoporos Int       Date:  2004-10-16       Impact factor: 4.507

4.  Usefulness of multi-detector CT in Boyd-Griffin type 2 intertrochanteric fractures with clinical correlation.

Authors:  Suk-Ku Han; Bae-Young Lee; Yong-Sik Kim; Nam-Yong Choi
Journal:  Skeletal Radiol       Date:  2009-09-08       Impact factor: 2.199

5.  Biopolymer augmentation of the lag screw in the treatment of femoral neck fractures--a biomechanical in-vitro study.

Authors:  A Paech; E Wilde; A P Schulz; G Heinrichs; R Wendlandt; C Queitsch; B Kienast; Ch Jürgens
Journal:  Eur J Med Res       Date:  2010-04-08       Impact factor: 2.175

6.  The Debrunner-Cech valgus osteotomy in osteoporotic four-part intertrochanteric fractures.

Authors:  A O Shannak; H D Malkawi; S T Hadidi
Journal:  Int Orthop       Date:  1988       Impact factor: 3.075

7.  ["Cutting out" in pertrochanteric fractures--problem of osteoporosis?].

Authors:  F Bonnaire; A Weber; O Bösl; C Eckhardt; K Schwieger; B Linke
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

8.  A New Injectable Brushite Cement: First Results in Distal Radius and Proximal Tibia Fractures.

Authors:  Christian Ryf; Sabine Goldhahn; Marek Radziejowski; Michael Blauth; Beate Hanson
Journal:  Eur J Trauma Emerg Surg       Date:  2009-05-12       Impact factor: 3.693

9.  Feasibility Analysis of a Novel Method for the Estimation of Local Bone Mechanical Properties: A Preliminary Investigation of Different Pressure Rod Designs on Synthetic Cancellous Bone Models.

Authors:  Alexander Maslaris; Matthias Bungartz; Frank Layher; Timo Zippelius; Georg Matziolis; Olaf Brinkmann
Journal:  Arch Bone Jt Surg       Date:  2021-03

10.  Outcomes of osteoporotic trochanteric fractures treated with cement-augmented dynamic hip screw.

Authors:  Rakesh Kumar Gupta; Vinay Gupta; Navdeep Gupta
Journal:  Indian J Orthop       Date:  2012-11       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.