Literature DB >> 4019739

Clinical evaluation of the Lumac bioluminescence method for screening urine specimens.

E T Martin, J A Cote, L K Perry, W J Martin.   

Abstract

A bioluminescence method for screening urine cultures to provide rapid reporting of negative specimens and to select appropriate urine cultures for direct application of automated identification methods was evaluated. A total of 2,000 specimens were processed in the Lumac Biocounter (3M, St. Paul, Minn.), and the results were compared with quantitative culture techniques by using a 0.001-ml inoculating loop. A total of 841 specimens were positive by the bioluminescence method; 291 specimens were culture positive (greater than or equal to 50,000 CFU of one or two organisms per ml). Positive cultures represented more than 20 different organisms. Approximately two-thirds of the false-positive results represented mixed flora or pure cultures of less than 5 X 10(4) organisms per ml. The predictive value of a negative result was 98.4%, reflecting a false-negative rate of only 0.7%. No advantages in cost or technician time were noted, but the Lumac method appears to be a useful technique in decreasing reporting time, especially for negative urine cultures.

Mesh:

Substances:

Year:  1985        PMID: 4019739      PMCID: PMC268312          DOI: 10.1128/jcm.22.1.19-22.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Urine screening strategy employing dipstick analysis and selective culture: an evaluation.

Authors:  S Y Loo; A G Scottolini; S Luangphinith; A L Adam; L D Jacobs; A J Mariani
Journal:  Am J Clin Pathol       Date:  1984-05       Impact factor: 2.493

2.  Clinical laboratory evaluation of a bacteriuria detection device for urine screening.

Authors:  J R Davis; C E Stager; G F Araj
Journal:  Am J Clin Pathol       Date:  1984-01       Impact factor: 2.493

3.  Comparison of the Lumac and Monolight systems for detection of bacteriuria by bioluminescence.

Authors:  D L Drow; C H Baum; G Hirschfield
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

4.  Evaluation of two bioluminescence-measuring instruments, the Turner Design and Lumac systems, for the rapid screening of urine specimens.

Authors:  W D Welch; L Thompson; M Layman; P M Southern
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

5.  Rapid method for identification and susceptibility testing of Escherichia coli bacteriuria.

Authors:  F E Dennstedt; C E Stager; J R Davis
Journal:  J Clin Microbiol       Date:  1983-07       Impact factor: 5.948

6.  Bacteriuria screening by direct bioluminescence assay of ATP.

Authors:  R B Schifman; M Wieden; J Brooker; M Chery; M Delduca; K Norgard; C Palen; N Reis; J Swanson; J White
Journal:  J Clin Microbiol       Date:  1984-10       Impact factor: 5.948

  6 in total
  1 in total

1.  Rapid screening for bacteriuria in pregnancy.

Authors:  W Graninger; D Fleischmann; B Schneeweiss; L Aram; F Stockenhuber
Journal:  Infection       Date:  1992 Jan-Feb       Impact factor: 3.553

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.