Literature DB >> 4019277

Clinical experience with a computerized record and verify system.

K C Podmaniczky, R Mohan, G J Kutcher, C Kestler, B Vikram.   

Abstract

To improve the quality of patient care by detecting and preventing many types of treatment mistakes, we have implemented a computerized system for recording and verifying external beam radiation treatments on our therapy machines. It inhibits the radiation beam if treatment machine settings do not agree with prescribed values to within maximum permissible deviations (tolerances). The tolerances are determined from experience and adjusted when necessary to make the system more effective and less susceptible to "false alarms." The system uses a common data base for all treatment machines. As a result, it permits statistical analysis and generation of reports based on data encompassing the entire patient population as well as verification of treatments of patients transferred from one machine to another. Reports of verification failures reveal patterns of mistakes. Knowing these, attempts can be made to reduce the frequency of verification failures. "Significant" mistakes that were prevented are extracted by treatment planning personnel from these reports. Analysis of data indicates a rate of approximately 150 "significant" mistakes detected and prevented per machine per year, representing 1.0% of all fields treated. We present and discuss our experiences with the system and with the frequency, patterns, and significance of verification failures. We selected a few of the patients for whose treatments significant set-up mistakes were made, and were detected and prevented by the Record and Verify System. We include discussions of the overall effect these mistakes would have had on dose distribution had they not been prevented.

Entities:  

Mesh:

Year:  1985        PMID: 4019277     DOI: 10.1016/0360-3016(85)90342-6

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  3 in total

1.  SafetyNet: Streamlining and Automating QA in radiotherapy.

Authors:  Scott W Hadley; Marc L Kessler; Dale W Litzenberg; Choonik Lee; Jim Irrer; Xiaoping Chen; Eduardo Acosta; Grant Weyburne; Wayne Keranen; Kwok Lam; Elizabeth Covington; Kelly C Younge; Martha M Matuszak; Jean M Moran
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

2.  An Investigation of Radiation Treatment Learning Opportunities in Relation to the Radiation Oncology Electronic Medical Record: A Single Institution Experience.

Authors:  Y Jessica Huang; Vikren Sarkar; Adam Paxton; Hui Zhao; Frances Fan-Chi Su; Ryan Price; Bill J Salter
Journal:  Adv Radiat Oncol       Date:  2021-09-29

3.  Analysis of couch position tolerance limits to detect mistakes in patient setup.

Authors:  Scott W Hadley; James M Balter; Kwok L Lam
Journal:  J Appl Clin Med Phys       Date:  2009-10-29       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.