Literature DB >> 4008503

Elbow joint contact study: comparison of techniques.

T J Stormont, K N An, B F Morrey, E Y Chao.   

Abstract

Elucidation of the contact areas between joint surfaces is important to both prosthetic design and the understanding of degeneration of articular cartilage. Numerous experimental methods are available to study joint contact, including cartilage staining, joint space casting, and pressure sensitive film techniques. This study attempts to compare the ability of each experimental technique to determine elbow joint contact. The silicone casting technique appears to be the best method to study joint contact area. The effects of magnitude and orientation of applied forces on the elbow joint contact patterns are studied.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 4008503     DOI: 10.1016/0021-9290(85)90288-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Intra-articular compressive stress of the elbow joint in extension: an experimental study using Fuji films.

Authors:  C Chantelot; G Wavreille; C Dos Remedios; B Landejerit; C Fontaine; H Hildebrand
Journal:  Surg Radiol Anat       Date:  2008-01-29       Impact factor: 1.246

2.  A topographical study of cartilaginous lesions to the elbow.

Authors:  C Debouck; M Rooze
Journal:  Surg Radiol Anat       Date:  1995       Impact factor: 1.246

Review 3.  Joint contact stress: a reasonable surrogate for biological processes?

Authors:  Richard A Brand
Journal:  Iowa Orthop J       Date:  2005

4.  Physiological incongruity of the humero-ulnar joint: a functional principle of optimized stress distribution acting upon articulating surfaces?

Authors:  F Eckstein; F Löhe; E Schulte; M Müller-Gerbl; S Milz; R Putz
Journal:  Anat Embryol (Berl)       Date:  1993-11

5.  The effect of post-fixation olecranon lengthening on range of motion of the elbow: a cadaveric study.

Authors:  Khai Phang Wong; James Chung Hui Tan
Journal:  BMC Musculoskelet Disord       Date:  2021-12-20       Impact factor: 2.362

6.  Changes in elbow joint contact area in symptomatic valgus instability of the elbow in baseball players.

Authors:  Kyosuke Numaguchi; Daisuke Momma; Yuki Matsui; Jun Oohinata; Takayoshi Yamaguchi; Nozomu Inoue; Eiji Kondo; Norimasa Iwasaki
Journal:  Sci Rep       Date:  2021-10-05       Impact factor: 4.379

7.  The Biomechanical Effect of Loading Speed on Metal-on-UHMWPE Contact Mechanics.

Authors:  Radovan Zdero; Zahra S Bagheri; Mojtaba Rezaey; Emil H Schemitsch; Habiba Bougherara
Journal:  Open Biomed Eng J       Date:  2014-05-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.