Literature DB >> 4006178

Factors affecting the development of precipitating antibodies in workers exposed to contaminated humidifiers.

M J Finnegan, C A Pickering, P S Davies, P K Austwick.   

Abstract

A total of 601 sera from groups of workers exposed to heavily and moderately contaminated humidifiers respectively were examined by the double diffusion test for precipitating antibodies to humidifier extracts. Clinical information was obtained using a standardized questionnaire. Skin-prick tests to control, to three common inhalant antigens and to an extract from the humidifier were performed in 103 subjects exposed to a heavily contaminated humidifier. In this environment a strong inverse relationship between current smoking and precipitins was detected (P less than 0.001). Pack years smoked had no bearing on precipitin level. In the larger study there was a clear dose response effect of smoking on precipitins. The effect of smoking appeared to reverse within 3 years. Duration of exposure also had a major effect on the development of precipitins with a clear 'dose response' again being seen in the larger study. These relationships did not apply in the groups exposed to moderately contaminated humidifiers. Levels of airborne antigen were measured using a competitive ELISA inhibition assay and were found to be much lower in sites with moderately contaminated humidifiers than at sites with heavily contaminated humidifiers. Our results suggest that the airborne antigen level is crucial in determining the pattern and strength of precipitin response in smokers and non-smokers exposed to contaminated humidifiers.

Mesh:

Substances:

Year:  1985        PMID: 4006178     DOI: 10.1111/j.1365-2222.1985.tb02286.x

Source DB:  PubMed          Journal:  Clin Allergy        ISSN: 0009-9090


  7 in total

1.  The effect of smoking on the development of allergic disease and specific immunological responses in a factory workforce exposed to humidifier contaminants.

Authors:  M J Finnegan; S Little; D J Gordon; P K Austwick; R D Tee; A J Nunn; A J Newman-Taylor
Journal:  Br J Ind Med       Date:  1991-01

2.  [Various forms of humidifier lung].

Authors:  R Hauck; X Baur
Journal:  Klin Wochenschr       Date:  1990-05-17

3.  Precipitating antibodies and positive skin tests in workers exposed to airborne antigens from a contaminated humidification system.

Authors:  A M Kremer; T M Pal; J G de Monchy; H F Kauffman; K de Vries
Journal:  Int Arch Occup Environ Health       Date:  1989       Impact factor: 3.015

4.  Extrinsic allergic alveolitis caused by a cold water humidifier.

Authors:  A S Robertson; P S Burge; G A Wieland; M H Carmalt
Journal:  Thorax       Date:  1987-01       Impact factor: 9.139

5.  Level of airborne bovine epithelial antigen in Finnish cowsheds.

Authors:  T Virtanen; P Vilhunen; K Husman; P Happonen; R Mäntyjärvi
Journal:  Int Arch Occup Environ Health       Date:  1988       Impact factor: 3.015

6.  Discriminant analysis of symptom pattern and serum antibody titres in humidifier related disease.

Authors:  C McSharry; K Anderson; A Speekenbrink; C Lewis; G Boyd
Journal:  Thorax       Date:  1993-05       Impact factor: 9.139

7.  Etiological diagnosis of pneumonia in military conscripts by combined use of bacterial culture and serological methods.

Authors:  K Lehtomäki; M Leinonen; A Takala; T Hovi; E Herva; M Koskela
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1988-06       Impact factor: 3.267

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.