Literature DB >> 3980529

Osteolytic changes in the upper femoral shaft following porous-coated hip replacement.

I W Brown, P A Ring.   

Abstract

Ten uncemented total hip replacements were performed in 1975 using an implant in which the cobalt-chrome femoral stem was coated to give a porous surface. In all but one case a high-density polyethylene head was used. The radiological changes in the upper femoral shafts were assessed between three and nine years later. Seven showed extensive stress-relieving changes, loss of calcar, stress fractures at the root of the lesser trochanter with subsequent detachment, and osteoporosis followed by avulsion of the greater trochanter. In these seven patients the lower part of the stem appeared to be soundly embedded, although in only one was there evidence of bony incorporation. It is suggested that if the fixation of a fully coated implant of this sort remains sound, gross atrophy of the upper femoral shaft develops after five years. This atrophy, associated with an implant which can be removed only at the expense of further bone destruction, presents substantial problems if revision is needed.

Entities:  

Mesh:

Year:  1985        PMID: 3980529

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  Two-stage management of a spontaneous fracture of the greater trochanter through osteolytic lesions induced by polyethylene wear of a total hip arthroplasty. A case report.

Authors:  Dario Regis; Andrea Sandri; Elena Samaila; Bruno Magnan
Journal:  Acta Biomed       Date:  2019-01-10

2.  Long term results of uncemented Judet hip endoprostheses.

Authors:  D Bettin; B Greitemann; J Polster; S Schulte-Eistrup
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

3.  High incidence of early subtrochanteric lateral cortical atrophy after hip arthroplasty using bone-conserving short stem.

Authors:  Yoon Je Cho; Chan Il Bae; Wan Keun Yoon; Young Soo Chun; Kee Hyung Rhyu
Journal:  Int Orthop       Date:  2017-07-05       Impact factor: 3.075

4.  Granulomatous pseudotumors in total joint replacement.

Authors:  H J Griffiths; J Burke; T A Bonfiglio
Journal:  Skeletal Radiol       Date:  1987       Impact factor: 2.199

5.  Excessive distal migration of fiber-mesh coated femoral stems.

Authors:  Thomas Baad-Hansen; Søren Kold; Niels Olsen; Finn Christensen; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-04-19       Impact factor: 3.717

6.  Effect of apexification on occlusal resistance of immature teeth.

Authors:  WooCheol Lee; Yeon-Jee Yoo
Journal:  BMC Oral Health       Date:  2020-11-12       Impact factor: 2.757

7.  Preparation of the femoral bone cavity in cementless stems: broaching versus compaction.

Authors:  Mette H Hjorth; Maiken Stilling; Kjeld Søballe; Poul Torben Nielsen; Poul H Christensen; Søren Kold
Journal:  Acta Orthop       Date:  2016-10-19       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.