Literature DB >> 3979845

Design considerations for a fluorophotometer for ocular research.

C R Munnerlyn, J R Gray, D R Hennings.   

Abstract

Fluorometric studies have been made with modified slit-lamp microscopes. These instruments offered considerable versatility in modifying experimental parameters, but were seldom optimized in terms of detector and illuminator apertures, filter band-pass characteristics, detection system, light-source stabilization, or optical resolution. Improper control of these parameters can result in artifacts which override useful information. A new fluorophotometer for ocular research has been designed that utilizes an optical system, which eliminates the need for a contact lens. An effort was made to optimize both the axial resolution and the minimum detectable signal. The characteristics of standard barrier filters and excitation filters were examined and compared with photomultiplier sensitivity curves. It was necessary to use double filters in order to reduce artifacts due to excitation light that was not rejected by the barrier filter. In order to optimize the signal-to-noise ratio, a photon counting detection system was used. A dark current equivalent to 3 X 10(-10) g/ml allows a useful detection range of 1 X 10(-10) g/ml.

Mesh:

Substances:

Year:  1985        PMID: 3979845     DOI: 10.1007/bf02133676

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  6 in total

1.  Use of a xenon flash tube as the excitation source in a new slit-lamp fluorophotometer.

Authors:  R F Brubaker; R L Coakes
Journal:  Am J Ophthalmol       Date:  1978-10       Impact factor: 5.258

2.  A new objective fluorophotometer.

Authors:  D M MAURICE
Journal:  Exp Eye Res       Date:  1963-01       Impact factor: 3.467

3.  A new objective slit lamp fluorophotometer.

Authors:  S R Waltman; H E Kaufman
Journal:  Invest Ophthalmol       Date:  1970-04

4.  Early breakdown of the blood-retinal barrier in diabetes.

Authors:  J Cunha-Vaz; J R Faria de Abreu; A J Campos
Journal:  Br J Ophthalmol       Date:  1975-11       Impact factor: 4.638

5.  Fluorescein angiography with an optimized filter combination.

Authors:  F Delori; I Ben-Sira; C Trempe
Journal:  Am J Ophthalmol       Date:  1976-10       Impact factor: 5.258

6.  Quantitative vitreous fluorophotometry. A sensitive technique for measuring early breakdown of the blood-retinal barrier in young diabetic patients.

Authors:  S R Waltman; C Oestrich; T Krupin; S Hanish; S Ratzan; J Santiago; C Kilo
Journal:  Diabetes       Date:  1978-02       Impact factor: 9.461

  6 in total
  9 in total

1.  Bioavailability of fluorescein from a new drug delivery system in human eyes.

Authors:  A Steinfeld; A Lux; S Maier; R Süverkrüp; M Diestelhorst
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

2.  Epithelial permeability reflects subclinical effects of contact lens wear.

Authors:  N A McNamara; R E Fusaro; R J Brand; K A Polse
Journal:  Br J Ophthalmol       Date:  1998-04       Impact factor: 4.638

Review 3.  Tear exchange and contact lenses: a review.

Authors:  Alex Muntz; Lakshman N Subbaraman; Luigina Sorbara; Lyndon Jones
Journal:  J Optom       Date:  2015-01-07

4.  A new technique for tear film fluorophotometry.

Authors:  N Eter; M Göbbels
Journal:  Br J Ophthalmol       Date:  2002-06       Impact factor: 4.638

5.  Simultaneous evaluation of tear turnover and corneal epithelial permeability by fluorophotometry in normal subjects and patients with keratoconjunctivitis sicca (KCS).

Authors:  J D Nelson
Journal:  Trans Am Ophthalmol Soc       Date:  1995

6.  A measure of tear inflow in habitual scleral lens wearers with and without midday fogging.

Authors:  Kelsea V Skidmore; Maria K Walker; Jason D Marsack; Jan P G Bergmanson; William L Miller
Journal:  Cont Lens Anterior Eye       Date:  2018-11-16       Impact factor: 3.077

7.  The effect of isosorbide-mononitrate eye drops on the human intraocular pressure and aqueous humor dynamics.

Authors:  M Diestelhorst; B Hinzpeter; G K Krieglstein
Journal:  Int Ophthalmol       Date:  1991-07       Impact factor: 2.031

8.  Corneal epithelial permeability to fluorescein in humans by a multi-drop method.

Authors:  Sangly P Srinivas; Arushi Goyal; Deepti P Talele; Sanjay Mahadik; Rachapalle Reddi Sudhir; P Pavani Murthy; Sudhir Ranganath; Uday B Kompella; Prema Padmanabhan
Journal:  PLoS One       Date:  2018-06-19       Impact factor: 3.240

9.  Fluorophotometric Determination of Riboflavin Concentrations in a Human Artificial Anterior Chamber Model.

Authors:  Katja C Iselin; Michael A Thiel; Lucas M Bachmann; Philipp B Baenninger; Claude Kaufmann
Journal:  Transl Vis Sci Technol       Date:  2019-11-12       Impact factor: 3.283

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.