Selective plane removal in limited angle tomographic imaging.

D N Ghosh Roy, R A Kruger, B Yih, P Del Rio.   

Abstract

A method of improving a planar image in limited angle tomography by removing blurred image information from selected out-of-focus planes is discussed. Focused tomosynthesized images rather than individual projections are used. The necessary equations for removing the information from either two or four adjacent planes, produced with a symmetrical, but otherwise arbitrary blurring function, are developed and specialized to the geometry of circular tomography. Results of a phantom experiment illustrating the technique are presented.

Mesh:

Year:  1985        PMID: 3974527     DOI: 10.1118/1.595791

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach.

Authors:  Yue-Houng Hu; Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

Review 2.  Tomosynthesis imaging: at a translational crossroads.

Authors:  James T Dobbins
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  Application of boundary detection information in breast tomosynthesis reconstruction.

Authors:  Yiheng Zhang; Heang-Ping Chan; Berkman Sahiner; Yi-Ta Wu; Chuan Zhou; Jun Ge; Jun Wei; Lubomir M Hadjiiski
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

4.  Wavelet denoising for quantum noise removal in chest digital tomosynthesis.

Authors:  Tsutomu Gomi; Masahiro Nakajima; Tokuo Umeda
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-04-20       Impact factor: 2.924

5.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

6.  An in vitro evaluation of cone-beam breast CT methods.

Authors:  Kai Zeng; Laurie L Fajardo; Simon Kao; Edmund A Franken; Jeong Mi Park; Zhenxue Jing; Er-Wei Bai; Ge Wang
Journal:  J Xray Sci Technol       Date:  2008-10-01       Impact factor: 1.535

7.  Chest tomosynthesis: technical principles and clinical update.

Authors:  James T Dobbins; H Page McAdams
Journal:  Eur J Radiol       Date:  2009-07-18       Impact factor: 3.528

8.  Optimal parameters for clinical implementation of breast cancer patient setup using Varian DTS software.

Authors:  Sook Kien Ng; Piotr Zygmanski; Andrew Jeung; Hassan Mostafavi; Juergen Hesser; Jennifer R Bellon; Julia S Wong; Yulia Lyatskaya
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102