A Doppler echocardiographic method for calculating volume flow across the tricuspid valve: correlative laboratory and clinical studies.

E J Meijboom, S Horowitz, L M Valdes-Cruz, D J Sahn, D F Larson, C Oliveira Lima.   

Abstract

In this study we tested a two-dimensional Doppler echocardiographic method for measuring volume flow across the tricuspid valve. Five anesthetized, open-chest dogs had a calibrated electromagnetic flow probe placed on the ascending aorta. Volume flow across the tricuspid valve was controlled by creating a variable femoral-to-pulmonary arterial shunt. Since no standard plane provided a direct view of the tricuspid valve orifice, tricuspid flow area was estimated by calculating a fixed circular flow orifice from the maximal late diastolic diameter of the tricuspid anulus in a four-chamber view. Doppler-determined velocities across the tricuspid valve and tricuspid anulus images in the four-chamber view were obtained in inspiration and expiration. For 24 cardiac outputs (0.6 to 4.0 liters/min), inspiratory tricuspid flow determined by the Doppler method correlated minimally better (r = .90, SEE = 0.30 liter/min) than did expiratory measurements (r = .89, SEE = 0.35 liter/min) with the time-averaged systemic flow determined electromagnetically. Doppler-determined tricuspid volume flows in four-chamber and short-axis two-dimensional echocardiographic views from 10 children were then compared with values determined simultaneously by thermodilution during cardiac catheterization. In the children, Doppler-determined flows in short-axis and four-chamber views, both in inspiration and expiration, were similar; when results for the two views were averaged in inspiration and expiration, the tricuspid flows predicted by the Doppler method were highly correlated (r = .98, SEE = 0.48 liter/min) with the results of thermodilution. The two-dimensional Doppler echocardiographic method provides a means of estimating volume flow across the tricuspid valve noninvasively.

Entities:  

Mesh:

Year:  1985        PMID: 3971526     DOI: 10.1161/01.cir.71.3.551

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  Doppler measurement of cardiac output across prosthetic mitral valves.

Authors:  H Dittmann; W Voelker; K R Karsch; L Seipel
Journal:  Klin Wochenschr       Date:  1990-03-05

2.  Doppler echocardiographic evaluation of the normal human fetal heart.

Authors:  L D Allan; S K Chita; W Al-Ghazali; D C Crawford; M Tynan
Journal:  Br Heart J       Date:  1987-06

Review 3.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

Review 4.  Cardiac ultrasonography in structural abnormalities and arrhythmias. Recognition and treatment.

Authors:  M M Brook; N H Silverman; M Villegas
Journal:  West J Med       Date:  1993-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.