Literature DB >> 3964577

Vibration white finger and digital systolic pressure during cooling.

L Ekenvall, L E Lindblad.   

Abstract

A cold provocation test (measurement of finger systolic pressure during combined body and local finger cooling) was performed on 111 male patients exposed to vibration and with a typical history of cold induced white finger. A new method of calculating the test result is described--namely, digital systolic blood pressure in the cooled test finger as a percentage of the systolic pressure in the arm (DP%). The conventional way of calculating the result, the systolic pressure in the cooled test finger as a percentage of the systolic pressure in the test finger when heated to 30 degrees C, corrected for changes in systemic pressure by the use of a reference finger (FSP%), requires the measurement of the systolic pressure in a reference finger. The two ways of calculating the test results give a similar sensitivity (74% for FSP%, 79% for DP% if all histories are regarded as true) but the new method does not require pressure measurements in a reference finger. This makes the test easier to perform and the result easier to understand.

Entities:  

Mesh:

Year:  1986        PMID: 3964577      PMCID: PMC1007648          DOI: 10.1136/oem.43.4.280

Source DB:  PubMed          Journal:  Br J Ind Med        ISSN: 0007-1072


  7 in total

1.  Raynaud's phenomenon of occupational origin.

Authors:  W F ASHE; W T COOK; J W OLD
Journal:  Arch Environ Health       Date:  1962-10

2.  Studies on the diagnosis and pathogenesis of Raynaud's phenomenon of occupational origin.

Authors:  A Okada; T Yamashita; C Nagano; T Ikeda; A Yachi; S Shibata
Journal:  Br J Ind Med       Date:  1971-10

3.  A comparison of some methods of diagnosing Raynaud phenomena of occupational origin.

Authors:  B Hellstrom; K Myhre
Journal:  Br J Ind Med       Date:  1971-07

4.  Locally induced digital vasospasm detected by delayed rewarming in Raynaud's phenomenon of occupational origin.

Authors:  C Juul; S L Nielsen
Journal:  Br J Ind Med       Date:  1981-02

5.  Raynaud phenomena and finger systolic pressure during cooling.

Authors:  S L Nielsen
Journal:  Scand J Clin Lab Invest       Date:  1978-12       Impact factor: 1.713

6.  Measurement of digital blood pressure after local cooling.

Authors:  S L Nielsen; N A Lassen
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1977-11

7.  Digital blood pressure after local cooling as a diagnostic tool in traumatic vasospastic disease.

Authors:  L Ekenvall; L E Lindblad
Journal:  Br J Ind Med       Date:  1982-11
  7 in total
  26 in total

1.  A follow up study of vibration induced white finger in compensation claimants.

Authors:  M Bovenzi; A Della Vedova; C Negro
Journal:  Occup Environ Med       Date:  2005-04       Impact factor: 4.402

2.  Effect of prior exposure to hand-transmitted vibration on cold response of digital arteries.

Authors:  Massimo Bovenzi; Alexandra J L Welsh; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2006-08-17       Impact factor: 3.015

3.  Multicenter study on finger systolic blood pressure test for diagnosis of vibration-induced white finger.

Authors:  Yoshiro Nasu; Youichi Kurozawa; Yutaka Fujiwara; Hiroki Honma; Toshiro Yanai; Kenji Kido; Takashi Ikeda
Journal:  Int Arch Occup Environ Health       Date:  2007-10-25       Impact factor: 3.015

4.  A longitudinal study of finger systolic blood pressure and exposure to hand-transmitted vibration.

Authors:  Massimo Bovenzi; Flavia D'Agostin; Francesca Rui; Corrado Negro
Journal:  Int Arch Occup Environ Health       Date:  2007-09-26       Impact factor: 3.015

Review 5.  Diagnosis of vascular injuries caused by hand-transmitted vibration.

Authors:  N Harada; M H Mahbub
Journal:  Int Arch Occup Environ Health       Date:  2007-09-26       Impact factor: 3.015

6.  Serum endothelin concentrations in workers exposed to vibration.

Authors:  K T Palmer; H Mason
Journal:  Occup Environ Med       Date:  1996-02       Impact factor: 4.402

7.  A longitudinal study of vibration white finger, cold response of digital arteries, and measures of daily vibration exposure.

Authors:  Massimo Bovenzi
Journal:  Int Arch Occup Environ Health       Date:  2010-03       Impact factor: 3.015

8.  Standardization of finger systolic blood pressure (FSBP) cooling tests.

Authors:  Niels Olsen
Journal:  Environ Health Prev Med       Date:  2005-11       Impact factor: 3.674

9.  Vibration white finger: a follow up study.

Authors:  L Ekenvall; A Carlsson
Journal:  Br J Ind Med       Date:  1987-07

10.  Diagnostic value of finger thermometry and photoplethysmography in the assessment of hand-arm vibration syndrome.

Authors:  A Bogadi-Sare; M Zavalić
Journal:  Int Arch Occup Environ Health       Date:  1994       Impact factor: 3.015

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.