Comparison of an implanted abdominal aortic counterpulsation device with the intraaortic balloon pump in a heart failure model.

J N Nanas, J W Mason, Y Taenaka, D B Olsen.   

Abstract

The abdominal aortic counterpulsation device is a round pumping chamber with a valveless opening which is implanted retroperitoneally on the abdominal aorta. The Utah driver is connected to the device through an air conduit and is synchronized on the electrocardiographic signal to provide diastolic aortic augmentation. For comparison an intraaortic balloon was also driven by the Utah driver system. The abdominal aortic counterpulsation device (stroke volume = 30, 40 and 60 ml) and the intraaortic balloon pump (balloon volume = 20 ml) were tested in dogs with acute left ventricular failure. The abdominal aortic counterpulsation device was also tested in normal animals. In acute left ventricular failure the abdominal aortic counterpulsation device at a stroke volume of 30, 40 or 60 ml decreased left ventricular end-diastolic pressure by an average of 28.56 (p less than 0.001), 39.56 (p less than 0.001) and 44.14% (p less than 0.005), respectively; aortic end-diastolic pressure by 24.11 (p less than 0.001), 26.67 (p less than 0.001) and 19.57% (p less than 0.01); and aortic systolic pressure by 18.56 (p less than 0.002), 26.0 (p less than 0.001) and 22.43% (p less than 0.005). It increased cardiac index by 27.58 (p less than 0.02), 35.59 (p less than 0.005) and 43.42% (p less than 0.001) and it provided peak aortic diastolic augmentation of 64.5 (p less than 0.001), 69.78 (p less than 0.001) and 74.43% (p less than 0.001), respectively, above the control aortic end-diastolic pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 3958359     DOI: 10.1016/s0735-1097(86)80220-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  3 in total

1.  Superior performance of a paraaortic counterpulsation device compared to the intraaortic balloon pump.

Authors:  John V Terrovitis; Christos E Charitos; Elias J Tsolakis; Paraskevi Dolou; Charalampos N Pierrakos; Kostas X Siafakas; John N Nanas
Journal:  World J Surg       Date:  2003-11-05       Impact factor: 3.352

2.  Development and early testing of a simple subcutaneous counterpulsation device.

Authors:  Steven C Koenig; Paul A Spence; George M Pantalos; Robert D Dowling; Kenneth N Litwak
Journal:  ASAIO J       Date:  2006 Jul-Aug       Impact factor: 2.872

3.  Comparison of effects of extra-thoracic paraaortic counterpulsation to intraaortic balloon pump on circulatory support in acute heart failure.

Authors:  Jie-Min Zhang; Xiao-Cheng Liu; Zhi-Gang Liu; Long Zhao; Li Yang; Tian-Wen Liu; Guo-Wei He
Journal:  J Cardiothorac Surg       Date:  2015-11-24       Impact factor: 1.637

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.