Literature DB >> 3957982

Evaluation of the Noiles hinged knee prosthesis. A five-year study of seventeen knees.

R Shindell, R Neumann, J F Connolly, O M Jardon.   

Abstract

The Noiles hinged knee prosthesis has been reported to diminish sheer and tensile loading on the cement-bone interface. Theoretically, this should eliminate the complication of loosening, commonly reported in hinged total knee prostheses. We reviewed the cases of all of the patients who have been treated with the Noiles knee prosthesis at our institution. Eighteen knees in fourteen patients were available, seventeen of which were followed for more than five years. Although all of the prostheses did well initially, ten knees in eight patients (56 per cent) had failed by an average of thirty-two months postoperatively. These eight patients included four of the five who weighed more than ninety kilograms and all of those who had had a prior arthroplasty. The failures were clearly defined along the lines of sex distribution. Measurements on the radiographs showed a significant difference between sexes in the metaphyseal diameter and thus in the percentage of the femoral canal that was filled by the prosthesis and cement. We concluded that prosthetic design must incorporate cortical cement support to reduce stress at the cement-bone interface, especially in a medullary canal with a larger diameter.

Entities:  

Mesh:

Year:  1986        PMID: 3957982

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  5 in total

1.  Mid-term results for metaphyseal sleeves in revision knee surgery.

Authors:  Carlos Martin-Hernandez; Luis Javier Floria-Arnal; Maria Pilar Muniesa-Herrero; Teresa Espallargas-Doñate; Jose Adolfo Blanco-Llorca; Melchor Guillen-Soriano; Miguel Ranera-Garcia
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-17       Impact factor: 4.342

2.  Distal femoral replacement in nontumor cases with severe bone loss and instability.

Authors:  Keith R Berend; Adolph V Lombardi
Journal:  Clin Orthop Relat Res       Date:  2008-06-04       Impact factor: 4.176

3.  Finn/Orthopaedic Salvage System Distal Femoral Rotating-Hinge Megaprostheses in Oncologic Patients: Long-Term Complications, Reoperations, and Amputations.

Authors:  Koichi Ogura; Mohamed A Yakoub; Patrick J Boland; John H Healey
Journal:  J Bone Joint Surg Am       Date:  2021-04-21       Impact factor: 5.284

4.  Dislocation of Rotating Hinged Knee Prostheses in a Patient With Extensor Mechanism Dysfunction.

Authors:  Mohammed A Al Hassan; Omar A Salem; Emad J Alabsi
Journal:  Cureus       Date:  2022-04-12

5.  Posterior dislocation of the hinge-post extension in a rotating hinge total knee prosthesis.

Authors:  Givenchy Manzano; Ran Schwarzkopf
Journal:  Case Rep Orthop       Date:  2013-09-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.