Literature DB >> 3956118

Pressure-diameter relationships of segments of human finger arteries.

G J Langewouters, A Zwart, R Busse, K H Wesseling.   

Abstract

Pressure-diameter relationships of segments of human finger arteries, aged 57-85 years, were measured in vitro. The arteries, obtained at autopsy within 48 h after death, were stored in glucose-free Tyrode at 4 degrees C. Experiments began within 40 h after autopsy. The diameter responses to various transmural pressure changes, with and without the addition of noradrenaline to the Tyrode solution in the specimen chamber, were compared with the responses of freshly excised rat tail arteries. In general, pressure-diameter relations of human finger artery segments were similar to those of rat tail artery segments, with a steep slope in the collapse region near zero pressure. Also, spontaneous rhythmic contractions and myogenic activity induced by high transmural pressures were similar to those observed in the fresh rat tail arteries. Human finger arteries, however, could contract to complete closure both spontaneously and after addition of noradrenaline, while rat tail arteries did not. The diameter changes of the arterial segments during forced 1 Hz oscillations of 20-50 mm Hg (2.7-6.7 kPa) amplitude superimposed on a mean transmural pressure were substantially smaller than those during quasi-steady inflation-deflation ramps over the same pressure range, indicating the presence of a strong viscous wall component.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3956118     DOI: 10.1088/0143-0815/7/1/003

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  11 in total

1.  Optical blood pressure estimation with photoplethysmography and FFT-based neural networks.

Authors:  Xiaoman Xing; Mingshan Sun
Journal:  Biomed Opt Express       Date:  2016-07-12       Impact factor: 3.732

2.  Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger.

Authors:  R D Boehmer
Journal:  J Clin Monit       Date:  1987-10

3.  Influence of graded changes in vasomotor tone on the carotid arterial mechanics in live spontaneously hypertensive rats.

Authors:  P Lacolley; N Ghodsi; E Glazer; P Challande; A M Brissac; M E Safar; S Laurent
Journal:  Br J Pharmacol       Date:  1995-08       Impact factor: 8.739

4.  Demonstration of the need for the inclusion of parameter correlations in error estimation for non-linear curve-fitting.

Authors:  C J Boyd; M R Roach; M H Sherebrin; R N Rankin; A Fenster
Journal:  Med Biol Eng Comput       Date:  1994-03       Impact factor: 2.602

5.  Vibration plethysmography: a method for studying the visco-elastic properties of finger arteries.

Authors:  J Penaz; N Honzikova; P Jurak
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

6.  PPG Sensor Contact Pressure Should Be Taken Into Account for Cuff-Less Blood Pressure Measurement.

Authors:  Anand Chandrasekhar; Mohammad Yavarimanesh; Keerthana Natarajan; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  IEEE Trans Biomed Eng       Date:  2020-02-28       Impact factor: 4.538

7.  Phantom with pulsatile arteries to investigate the influence of blood vessel depth on pulse oximeter signal strength.

Authors:  Norbert Stuban; Masatsugu Niwayama; Hunor Santha
Journal:  Sensors (Basel)       Date:  2012-01-16       Impact factor: 3.576

8.  Differential regulation of nitric oxide synthase function in aorta and tail artery from 5/6 nephrectomized rats.

Authors:  Frank T Spradley; John J White; William D Paulson; David M Pollock; Jennifer S Pollock
Journal:  Physiol Rep       Date:  2013-11-05

9.  Uncertainty quantification and sensitivity analysis of an arterial wall mechanics model for evaluation of vascular drug therapies.

Authors:  Maarten H G Heusinkveld; Sjeng Quicken; Robert J Holtackers; Wouter Huberts; Koen D Reesink; Tammo Delhaas; Bart Spronck
Journal:  Biomech Model Mechanobiol       Date:  2017-07-28

10.  Accuracy of an autocalibrated pulse contour analysis in cardiac surgery patients: a bi-center clinical trial.

Authors:  Ole Broch; Jose Carbonell; Carlos Ferrando; Malte Metzner; Arne Carstens; Martin Albrecht; Matthias Gruenewald; Jan Höcker; Marina Soro; Markus Steinfath; Jochen Renner; Berthold Bein
Journal:  BMC Anesthesiol       Date:  2015-11-26       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.