Literature DB >> 3955963

A device to measure X-ray magnification in preoperative planning for cementless arthroplasty.

J M Gorski, L Schwartz.   

Abstract

Non-cemented press fit prostheses require a high degree of surgical precision for success. Since components vary in size by millimeters, the optimum preoperatively-determined size becomes a vital factor in selecting the correct size at the time of surgery. The preoperatively-determined component size is useful only if the information is obtained in a reliable and reproducible manner. The proper sequence combines X-rays of known magnification and templates of corresponding magnification. X-ray magnification is not a constant value even if the X-ray tube is maintained at a standardized height. Variables such as patient size and positioning make magnification measurements a necessity for every X-ray taken. A dense lead plate was designed for this purpose because commercially-available devices are over-penetrated by the X-ray exposures routinely used for hip roentgenograms. Manufacturers can provide templates in varying magnifications. This makes it possible to obtain a high correlation between the preoperative choice and the actual size chosen at surgery.

Entities:  

Mesh:

Year:  1986        PMID: 3955963

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  Comparison of techniques for correction of magnification of pelvic X-rays for hip surgery planning.

Authors:  Bertram The; Johan W J Kootstra; Anton H Hosman; Nico Verdonschot; Carina L E Gerritsma; Ron L Diercks
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

2.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

3.  Assessment of magnification of digital pelvic radiographs in total hip arthroplasty using templating software.

Authors:  S P White; J Bainbridge; E J Smith
Journal:  Ann R Coll Surg Engl       Date:  2008-10       Impact factor: 1.891

4.  A new digital preoperative planning method for total hip arthroplasties.

Authors:  Hendrikus J A Crooijmans; Armand M R P Laumen; Carola van Pul; Jan B A van Mourik
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

  4 in total