Ear oximetry during combined hypoxia and exercise.

R J Smyth, A D D'Urzo, A S Slutsky, B M Galko, A S Rebuck.   

Abstract

Ear oximetry is widely used to detect arterial O2 desaturation during exercise in patients with cardiopulmonary disease. Although oximeters have been evaluated for accuracy, response time, and the influence of skin pigmentation, tests of their reliability have not been reported during strenuous exercise. Accordingly, we compared arterial O2 saturation (Sao2) measurements obtained by Hewlett-Packard (HP, model 47201A) and Biox II oximeters with those determined directly from arterial blood in six healthy volunteers during progressive exercise while rebreathing hypoxic gas mixtures. The relationship between the HP oximeter value and blood Sao2 was described by the equation: HP = 0.93 (Sao2) + 5.37 and for the Biox II: Biox = 0.55 (Sao2) + 38.97. With these equations, at a blood Sao2 value of 90%, the underestimation by both oximeters was less than 2%. At a blood value of 70%, the HP oximeter overestimated blood Sao2 by 0.7%, whereas the Biox II showed an overestimation of 10.7%. Below blood Sao2 of 83%, the Biox II tended to overestimate blood Sao2 by an amount greater than the error of the instrument, whereas the HP estimations were within the error of the instrument over all levels of blood Sao2 studied. We conclude that the HP oximeter provides valid estimates of Sao2 during exercise but that the Biox II oximeter, although reflecting qualitative changes in oxygenation that occur during exercise, does not provide accurate records of the degree of desaturation.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3949671     DOI: 10.1152/jappl.1986.60.2.716

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  10 in total

Review 1.  Exercise testing in children: indications and technique.

Authors:  S Swaminathan
Journal:  Indian J Pediatr       Date:  1991 May-Jun       Impact factor: 1.967

2.  The difference in respiratory and blood gas values during recovery after exercise with spontaneous versus reduced breathing frequency.

Authors:  Jernej Kapus; Anton Ušaj; Venceslav Kapus; Boro Strumbelj
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

3.  Arterial hypoxemia and performance during intense exercise.

Authors:  M D Koskolou; D C McKenzie
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

4.  Respiratory sinus arrhythmia in dogs. Effects of phasic afferents and chemostimulation.

Authors:  B E Shykoff; S S Naqvi; A S Menon; A S Slutsky
Journal:  J Clin Invest       Date:  1991-05       Impact factor: 14.808

Review 5.  Pulmonary gas exchange and acid-base balance during exercise.

Authors:  Michael K Stickland; Michael I Lindinger; I Mark Olfert; George J F Heigenhauser; Susan R Hopkins
Journal:  Compr Physiol       Date:  2013-04       Impact factor: 9.090

6.  Re-examination of the incidence of exercise-induced hypoxaemia in highly trained subjects.

Authors:  D D Brown; R G Knowlton; P B Sanjabi; B T Szurgot
Journal:  Br J Sports Med       Date:  1993-09       Impact factor: 13.800

7.  Nedocromil sodium and diphenhydramine HCl ameliorate exercise-induced arterial hypoxemia in highly trained athletes.

Authors:  Michael A Coyle; Curtis S Goss; Wesley J Manz; Joel T Greenshields; Robert F Chapman; Joel M Stager
Journal:  Physiol Rep       Date:  2022-01

8.  The accuracy of pulse oximetry in measuring oxygen saturation by levels of skin pigmentation: a systematic review and meta-analysis.

Authors:  Chunhu Shi; Mark Goodall; Jo Dumville; James Hill; Gill Norman; Oliver Hamer; Andrew Clegg; Caroline Leigh Watkins; George Georgiou; Alexander Hodkinson; Catherine Elizabeth Lightbody; Paul Dark; Nicky Cullum
Journal:  BMC Med       Date:  2022-08-16       Impact factor: 11.150

9.  Peripheral chemoresponsiveness during exercise in male athletes with exercise-induced arterial hypoxaemia.

Authors:  Emily A Granger; Trevor K Cooper; Susan R Hopkins; Donald C McKenzie; Paolo Dominelli
Journal:  Exp Physiol       Date:  2020-09-12       Impact factor: 2.969

10.  Assessing exercise limitation using cardiopulmonary exercise testing.

Authors:  Michael K Stickland; Scott J Butcher; Darcy D Marciniuk; Mohit Bhutani
Journal:  Pulm Med       Date:  2012-11-19
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.