Evaluation of "HemoCue," a new device for determining hemoglobin.

H von Schenck, M Falkensson, B Lundberg.   

Abstract

Hemoglobinometry according to the International Committee of Standardization in Hematology (ICSH) suffers from imprecision related to high sample dilution and from potential errors owing to sample turbidity. We have evaluated a new instrument, "HemoCue," that measures hemoglobin at two wavelengths as azide methemoglobin, without dilution. The HemoCue method is superior to the ICSH method: by correction for turbidity, it avoids false hemoglobin readings that may arise from hyperlipemia or some large M-component of the immunoglobulin M class. We find the equipment suitable for use in outpatient units.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3948400

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  48 in total

1.  Validation of hemoglobin estimation using Hemocue.

Authors:  P Bhaskaram; N Balakrishna; K V Radhakrishna; Kamala Krishnaswamy
Journal:  Indian J Pediatr       Date:  2003-01       Impact factor: 1.967

2.  An accurate and inexpensive color-based assay for detecting severe anemia in a limited-resource setting.

Authors:  Patrick T McGann; Erika A Tyburski; Vysolela de Oliveira; Brigida Santos; Russell E Ware; Wilbur A Lam
Journal:  Am J Hematol       Date:  2015-10-12       Impact factor: 10.047

3.  Hemocue, an accurate bedside method of hemoglobin measurement?

Authors:  C E Rippmann; P C Nett; D Popovic; B Seifert; T Pasch; D R Spahn
Journal:  J Clin Monit       Date:  1997-11

4.  HemoCue photometer: a better alternative of hemoglobin estimation in blood donors?

Authors:  Kafil Akhtar; Rana K Sherwani; Khaliqur Rahman; Jaseem Hasan; Mohd Shahid
Journal:  Indian J Hematol Blood Transfus       Date:  2009-01-11       Impact factor: 0.900

5.  Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum hospital, Sudan.

Authors:  Ishag Adam; Samah Ahmed; Mahmoud H Mahmoud; Mohammed I Yassin
Journal:  Diagn Pathol       Date:  2012-03-21       Impact factor: 2.644

6.  Evaluation of a portable hemoglobin photometer in pregnant women in a high altitude area: a pilot study.

Authors:  Xiaoyan Zhou; Hong Yan; Yuan Xing; Shaonong Dang; Bianba Zhuoma; Duolao Wang
Journal:  BMC Public Health       Date:  2009-07-11       Impact factor: 3.295

7.  Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario.

Authors:  Rashmi Tondon; Anupam Verma; Prashant Pandey; Rajendra Chaudhary
Journal:  Asian J Transfus Sci       Date:  2009-07

8.  The association between cytokines and insulin sensitivity in Iraqi immigrants and native Swedes.

Authors:  Ashfaque A Memon; Jan Sundquist; Xiao Wang; Karolina Palmér; Kristina Sundquist; Louise Bennet
Journal:  BMJ Open       Date:  2013-11-29       Impact factor: 2.692

9.  Using clinical signs to diagnose anaemia in African children.

Authors:  S P Luby; P N Kazembe; S C Redd; C Ziba; O C Nwanyanwu; A W Hightower; C Franco; L Chitsulo; J J Wirima; M A Olivar
Journal:  Bull World Health Organ       Date:  1995       Impact factor: 9.408

10.  Point-of-care method for total white cell count: an evaluation of the HemoCue WBC device.

Authors:  A Osei-Bimpong; C Jury; R McLean; S M Lewis
Journal:  Int J Lab Hematol       Date:  2008-08-28       Impact factor: 2.877

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.