Literature DB >> 3938481

Continuous mixed venous oxygen saturation measurement: a significant advance in hemodynamic monitoring?

E A Norfleet, C B Watson.   

Abstract

Development of the flow-directed pulmonary artery catheter in combination with reflective fiberoptic oximetry techniques allows the clinician to continuously measure mixed venous oxygen saturation (SvO2). A brief review of the determinants of oxygen balance, the Fick principle, and the technology of continuous SvO2 monitoring is preliminary to a debate between two clinicians on the usefulness of SvO2 monitoring. One clinician highly recommends use of the flow-directed pulmonary artery catheter in patients who require pulmonary artery catheterization. Monitoring of SvO2 is described as a safe, convenient, and reliable option that is cost-effective. Continuous availability of this dynamic physiologic monitor is of great value in improving understanding of serious disturbances in oxygen balance, providing information for rapid diagnosis, and guiding therapeutic interventions. Another clinician suggests a less enthusiastic approach to SvO2 monitoring and argues that SvO2 is a nonspecific index of the matching of oxygen delivery with supply. Although it is a useful adjunct in specific clinical situations, it provides uncertain information in the presence of a number of diseases. Major mistakes in patient management could follow from overreliance upon either absolute SvO2 measurements or analysis of trends over time. Use of the SvO2 monitor has not been proven cost-effective and may actually increase monitoring costs. Both clinicians agree that continuous SvO2 monitoring is valuable in many clinical circumstances, provided the limitations of the measurement are understood.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3938481     DOI: 10.1007/bf02832818

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  35 in total

1.  Tissue blood flow and oxygen transport in critically ill patients.

Authors:  C W Bryan-Brown
Journal:  Crit Care Med       Date:  1975 May-Jun       Impact factor: 7.598

2.  High oxygen saturation does not always indicate arterial placement of catheter during internal jugular venous cannulation.

Authors:  A Aghdami; R Ellis
Journal:  Anesthesiology       Date:  1985-03       Impact factor: 7.892

3.  Sequential cardiorespiratory patterns in septic shock.

Authors:  E Abraham; W C Shoemaker; R D Bland; J C Cobo
Journal:  Crit Care Med       Date:  1983-10       Impact factor: 7.598

4.  Pulse oximetry.

Authors:  W New
Journal:  J Clin Monit       Date:  1985-04

5.  Mixed venous oxygen saturation. Its role in the assessment of the critically ill patient.

Authors:  G Kandel; A Aberman
Journal:  Arch Intern Med       Date:  1983-07

6.  Continuous mixed venous oxygen saturation monitoring for perioperative management of a boy undergoing a modified Fontan procedure.

Authors:  B G Fauss; K H Rah
Journal:  J Clin Monit       Date:  1985-01

7.  Nitroprusside.

Authors:  J N Cohn; L P Burke
Journal:  Ann Intern Med       Date:  1979-11       Impact factor: 25.391

8.  Clinical evaluation of a new fiberoptic catheter oximeter during cardiac surgery.

Authors:  J L Waller; J A Kaplan; D I Bauman; J M Craver
Journal:  Anesth Analg       Date:  1982-08       Impact factor: 5.108

9.  Continuous transcutaneous oxygen monitoring during respiratory failure, cardiac decompensation, cardiac arrest, and CPR. Transcutaneous oxygen monitoring during arrest and CPR.

Authors:  K K Tremper; K Waxman; R Bowman; W C Shoemaker
Journal:  Crit Care Med       Date:  1980-07       Impact factor: 7.598

10.  Continuous in vivo oxygen saturation in newborn infants with pulmonary disease: a new fiberoptic catheter oximeter.

Authors:  A R Wilkinson; R H Phibbs; G A Gregory
Journal:  Crit Care Med       Date:  1979-05       Impact factor: 7.598

View more
  1 in total

1.  Continuous mixed venous oxygen saturation during recurrent nodal rhythm: an unusual waveform trend.

Authors:  E Segal; K R Courington; R M Joshi; T J Gallagher
Journal:  J Clin Monit       Date:  1992-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.